FireCADCalc

Fuel Rod Temperatures: Centreline, Gap, Clad and Film

Temperatures through a fuel rod from coolant to pellet centreline at a given linear heat rate: film, cladding, gap and pellet conduction drops.

Thermal power plant

Inputs

Examples: Illustrative PWR rod at 18 kW/mPeak 40 kW/m, closed gap 10000BWR rod 30 kW/m, 5.2 mm pellet, boiling h 100000

Accepted: 0.1 to 100 kW/m
Accepted: 1 to 20 mm
Accepted: 0 to 1 mm
Accepted: 0.1 to 3 mm
Accepted: 0.5 to 50 W/(m·K)
Accepted: 100 to 100,000 W/(m²·K)
Accepted: 1 to 400 W/(m·K)
Accepted: 0 to 1,026.8 °C
Accepted: 100 to 200,000 W/(m²·K)

Results

Steady radial conduction with uniform heat generation in the pellet and constant conductivities; gap conductance referred to the pellet surface. UO₂ conductivity falls with temperature, so a constant value underestimates the centreline temperature at high power; use the conductivity integral for design.

Volumetric heat generation in the pellet353.15MW/m³
Heat flux at the clad outer surface794.45kW/m²
Clad outer surface temperature293.94°C
Clad inner surface temperature329.25°C
Pellet surface temperature512.89°C
Pellet centreline temperature1,308.7°C
Temperature drop across the pellet795.77K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PWR rod at 18 kW/m. The inputs, in the units selected above:

InputValue
Linear heat rate18.000 kW/m
Pellet radius4.1000 mm
Radial gap width0.080000 mm
Cladding thickness0.57000 mm
Fuel thermal conductivity (UO₂ about 2.5–4)3.0000 W/(m·K)
Gap conductance6,000.0 W/(m²·K)
Cladding thermal conductivity (Zircaloy about 17)17.000 W/(m·K)
Bulk coolant temperature310.00 °C
Coolant heat transfer coefficient34,000 W/(m²·K)

Applying the formula below gives:

ResultValue
Volumetric heat generation in the pellet340.84 MW/m³
Heat flux at the clad outer surface603.11 kW/m²
Clad outer surface temperature327.74 °C
Clad inner surface temperature349.28 °C
Pellet surface temperature465.74 °C
Pellet centreline temperature943.20 °C
Temperature drop across the pellet477.46 K

Open this example in the calculator and change any input.

Formula

\(T_{max} - T_b = q'\left[\frac{1}{4\pi k_f} + \frac{1}{2\pi r_f h_g} + \frac{\ln(r_{co}/r_{ci})}{2\pi k_c} + \frac{1}{2\pi r_{co}h}\right]\)

Variables

Symbol Meaning SI unit
\(q'\) Linear heat rate W/m
\(r_f\) Pellet radius m
\(\delta_g\) Radial gap width m
\(t_c\) Cladding thickness m
\(k_f\) Fuel thermal conductivity (UO₂ about 2.5–4) W/(m·K)
\(h_g\) Gap conductance W/(m²·K)
\(k_c\) Cladding thermal conductivity (Zircaloy about 17) W/(m·K)
\(T_b\) Bulk coolant temperature K
\(h\) Coolant heat transfer coefficient W/(m²·K)
\(q'''\) Volumetric heat generation in the pellet W/m³
\(q''\) Heat flux at the clad outer surface W/m²
\(T_{co}\) Clad outer surface temperature K
\(T_{ci}\) Clad inner surface temperature K
\(T_{fs}\) Pellet surface temperature K
\(T_{max}\) Pellet centreline temperature K
\(\Delta T_f\) Temperature drop across the pellet K

Method and standards

Series thermal resistances of a fuel rod.

Where it is used

  • Fuel design margins to melting.
  • Teaching nuclear heat transfer.

Common mistakes

  • Using the clad outer radius for the gap conductance.
  • Using a constant fuel conductivity at very high power.

Assumptions and limits

  • Steady state; uniform generation; constant properties.

References

  • Radial conduction in a fuel rod with uniform heat generation

Questions and answers

Why is the pellet drop independent of radius?

ΔT = q'/(4πk): for a given linear heat rate, a fatter pellet generates the same heat per metre at a lower density; the two effects cancel.

Where is the largest temperature drop?

In the UO₂ pellet: its conductivity is only about 3 W/(m·K), so 18 kW/m gives a drop of nearly 500 K.

What do the defaults represent?

An illustrative PWR rod at 18 kW/m: 4.1 mm pellet radius, 0.08 mm gap at 6,000 W/(m²·K), 0.57 mm Zircaloy cladding, coolant 310 °C at 34,000 W/(m²·K).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...