FireCADCalc

Fuel Reproduction Factor and Thermal Utilisation

Reproduction factor eta of enriched uranium and the thermal utilisation f of a homogeneous fuel-moderator mixture from enrichment, cross-sections and atom ratio.

Thermal power plant

Inputs

Examples: Illustrative 3 % in water, 4 molecules per U atomNatural uranium in graphite, 400 C atoms per UHighly enriched 93 % in water, 300 per U

Accepted: 0.72 to 100 %
Accepted: 2 to 3.2
Accepted: 1 to 10,000 b
Accepted: 1 to 10,000 b
Accepted: 0 to 100 b
Accepted: 0 to 100,000
Accepted: 0 to 100 b

Results

η = νσ_f,5 e/[eσ_a,5 + (1 − e)σ_a,8] and f = Σ_a,U/(Σ_a,U + Σ_a,M) for a homogeneous mixture. Cross-sections are at 0.0253 eV by default; for a hot core use spectrum-averaged values (the non-1/v factors matter for U-235). Cladding and structure absorption lower f further.

Reproduction factor1.3532
Thermal utilisation84.760%
Product ηf1.1469
Absorption cross-section per uranium atom7.5639b

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3 % in water, 4 molecules per U atom. The inputs, in the units selected above:

InputValue
Enrichment (U-235 atom fraction)3.0000 %
Neutrons per fission (U-235 thermal 2.43)2.4300 -
U-235 fission cross-section585.00 b
U-235 absorption cross-section681.00 b
U-238 absorption cross-section2.6800 b
Moderator molecules per uranium atom4.0000 -
Moderator absorption cross-section per molecule (H₂O 0.664 b)0.66400 b

Applying the formula below gives:

ResultValue
Reproduction factor1.8518
Thermal utilisation89.660 %
Product ηf1.6603
Absorption cross-section per uranium atom23.030 b

Open this example in the calculator and change any input.

Formula

\(\eta = \frac{\nu e\sigma_{f,5}}{e\sigma_{a,5} + (1 - e)\sigma_{a,8}}, \quad f = \frac{\sigma_{a,U}}{\sigma_{a,U} + (N_M/N_U)\sigma_{a,M}}\)

Variables

Symbol Meaning SI unit
\(e\) Enrichment (U-235 atom fraction) -
\(\nu\) Neutrons per fission (U-235 thermal 2.43) -
\(\sigma_{f,5}\) U-235 fission cross-section m²
\(\sigma_{a,5}\) U-235 absorption cross-section m²
\(\sigma_{a,8}\) U-238 absorption cross-section m²
\(N_M/N_U\) Moderator molecules per uranium atom -
\(\sigma_{a,M}\) Moderator absorption cross-section per molecule (H₂O 0.664 b) m²
\(\eta\) Reproduction factor -
\(f\) Thermal utilisation -
\(\eta f\) Product ηf -
\(\sigma_{a,U}\) Absorption cross-section per uranium atom m²

Method and standards

Homogeneous one-group factors.

Where it is used

  • Enrichment and moderation studies.
  • Teaching reactor physics.

Common mistakes

  • Using weight per cent enrichment as atom fraction (slightly different).
  • Forgetting the molecule count for water (two hydrogens per molecule).

Assumptions and limits

  • Homogeneous mixture; no self-shielding or disadvantage factor.

References

  • One-group thermal factors for a homogeneous fuel-moderator mixture

Questions and answers

Why does natural uranium have η of only 1.33?

Its 0.72 % U-235 has to compete with 99.3 % U-238 that absorbs without fission; at 3 % enrichment η rises to about 1.84.

Why does more water lower f?

Every extra moderator molecule absorbs thermal neutrons; in a light-water reactor this is balanced against better resonance escape.

What do the defaults represent?

An illustrative 3 % enriched uranium in water at 4 molecules per uranium atom, with 2,200 m/s cross-sections.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.