FireCADCalc

Neutron Flux from Foil Activation Measurement

Neutron flux from the measured activity of an activation foil (for example gold) from its mass, cross-section, half-life, irradiation and decay times.

Thermal power plant

Inputs

Examples: Illustrative 0.1 mg gold foil, 1 h, counted after 2 hIndium foil 54 min, 4 h irradiationCobalt wire 10 h, counted after 1 day

Accepted: 1E-6 to 1E+12 kBq
Accepted: 0.001 to 10,000 mg
Accepted: 1 to 260 kg/kmol
Accepted: 0 to 100 %
Accepted: 0.0001 to 10,000 b
Accepted: 1.157E-5 to 11,574,000 d
Accepted: 0.00027778 to 2,777,800 h
Accepted: 0 to 2,777,800 h

Results

Inverting A = Nσφ(1 − e^(−λt_i))e^(−λt_d). Thin foils avoid self-shielding; bare and cadmium-covered foils separate thermal and epithermal flux. Correct the measured activity for detector efficiency first.

Target atoms2.5100e+17
Saturation activity23,837kBq
Neutron flux5.8622e+111/(cm²·s)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 0.1 mg gold foil, 1 h, counted after 2 h. The inputs, in the units selected above:

InputValue
Measured foil activity at counting3,000.0 kBq
Foil mass0.10000 mg
Molar mass196.97 kg/kmol
Isotopic abundance100.00 %
Activation cross-section (spectrum-averaged)98.650 b
Product half-life2.6941 d
Irradiation time1.0000 h
Time from end of irradiation to counting2.0000 h

Applying the formula below gives:

ResultValue
Target atoms3.0574e+17
Saturation activity287,447 kBq
Neutron flux9.5302e+12 1/(cm²·s)

Open this example in the calculator and change any input.

Formula

\(\phi = \frac{Ae^{\lambda t_d}}{N\sigma\left(1 - e^{-\lambda t_i}\right)}\)

Variables

Symbol Meaning SI unit
\(A\) Measured foil activity at counting Bq
\(m\) Foil mass kg
\(M\) Molar mass kg/kmol
\(\theta\) Isotopic abundance -
\(\sigma\) Activation cross-section (spectrum-averaged) m²
\(T_{1/2}\) Product half-life s
\(t_i\) Irradiation time s
\(t_d\) Time from end of irradiation to counting s
\(N\) Target atoms -
\(A_{sat}\) Saturation activity Bq
\(\phi\) Neutron flux 1/(m²·s)

Method and standards

Foil flux measurement.

Where it is used

  • Research reactor and source calibration.
  • Teaching neutron measurements.

Common mistakes

  • Forgetting decay between irradiation and counting.
  • Ignoring self-shielding in thick foils.

Assumptions and limits

  • Constant flux; thin foil; detector efficiency already applied.

References

  • Activation-foil flux measurement

Questions and answers

Why gold foils?

Gold-197 is a single isotope with a large, well-known capture cross-section and a convenient 2.7-day half-life.

Why use a cadmium cover?

Cadmium absorbs thermal neutrons; comparing bare and covered foils separates thermal from epithermal activation.

What do the defaults represent?

An illustrative 0.1 mg gold foil (98.65 b) irradiated for 1 hour, counted 2 hours later at a measured activity of 3 MBq (a flux near 10¹³ per cm² per second, typical of a research reactor).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.