Worked example
Example: Illustrative 0.1 mg gold foil, 1 h, counted after 2 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured foil activity at counting | 3,000.0 kBq |
| Foil mass | 0.10000 mg |
| Molar mass | 196.97 kg/kmol |
| Isotopic abundance | 100.00 % |
| Activation cross-section (spectrum-averaged) | 98.650 b |
| Product half-life | 2.6941 d |
| Irradiation time | 1.0000 h |
| Time from end of irradiation to counting | 2.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Target atoms | 3.0574e+17 |
| Saturation activity | 287,447 kBq |
| Neutron flux | 9.5302e+12 1/(cm²·s) |
Open this example in the calculator and change any input.
Formula
\(\phi = \frac{Ae^{\lambda t_d}}{N\sigma\left(1 - e^{-\lambda t_i}\right)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Measured foil activity at counting | Bq |
| \(m\) | Foil mass | kg |
| \(M\) | Molar mass | kg/kmol |
| \(\theta\) | Isotopic abundance | - |
| \(\sigma\) | Activation cross-section (spectrum-averaged) | m² |
| \(T_{1/2}\) | Product half-life | s |
| \(t_i\) | Irradiation time | s |
| \(t_d\) | Time from end of irradiation to counting | s |
| \(N\) | Target atoms | - |
| \(A_{sat}\) | Saturation activity | Bq |
| \(\phi\) | Neutron flux | 1/(m²·s) |
Method and standards
Foil flux measurement.
Where it is used
- Research reactor and source calibration.
- Teaching neutron measurements.
Common mistakes
- Forgetting decay between irradiation and counting.
- Ignoring self-shielding in thick foils.
Assumptions and limits
- Constant flux; thin foil; detector efficiency already applied.
References
- Activation-foil flux measurement
Questions and answers
Why gold foils?
Gold-197 is a single isotope with a large, well-known capture cross-section and a convenient 2.7-day half-life.
Why use a cadmium cover?
Cadmium absorbs thermal neutrons; comparing bare and covered foils separates thermal from epithermal activation.
What do the defaults represent?
An illustrative 0.1 mg gold foil (98.65 b) irradiated for 1 hour, counted 2 hours later at a measured activity of 3 MBq (a flux near 10¹³ per cm² per second, typical of a research reactor).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 2