Worked example
Example: Illustrative I-131, 3000 MW, 1 year, 2 days decay. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reactor thermal power | 3,000.0 MW |
| Cumulative fission yield of the nuclide (I-131 about 0.029) | 2.8900 % |
| Half-life of the nuclide | 8.0252 d |
| Operating time at power | 365.00 d |
| Time after shutdown | 2.0000 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fission rate | 9.3623e+19 1/s |
| Saturation activity γF | 2,705.7 PBq |
| Activity at shutdown | 2,705.7 PBq |
| Activity after the decay time | 2,276.4 PBq |
| Activity per MW thermal at shutdown (Ci) | 24,376 |
Open this example in the calculator and change any input.
Formula
\(A = \gamma\frac{P}{E_f}\left(1 - e^{-\lambda T_{op}}\right)e^{-\lambda t_d}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Reactor thermal power | W |
| \(\gamma\) | Cumulative fission yield of the nuclide (I-131 about 0.029) | - |
| \(T_{1/2}\) | Half-life of the nuclide | s |
| \(T_{op}\) | Operating time at power | s |
| \(t_d\) | Time after shutdown | s |
| \(\dot F\) | Fission rate | 1/s |
| \(A_{sat}\) | Saturation activity γF | Bq |
| \(A_0\) | Activity at shutdown | Bq |
| \(A\) | Activity after the decay time | Bq |
| \(A/P\) | Activity per MW thermal at shutdown (Ci) | - |
Method and standards
Fission product inventory.
Where it is used
- Accident source terms and emergency planning.
- Spent fuel and waste characterisation.
Common mistakes
- Using independent instead of cumulative yields.
- Ignoring capture for strongly absorbing nuclides (Xe-135).
Assumptions and limits
- Constant power; no neutron capture of the product.
References
- Fission product build-up and decay
Questions and answers
How much iodine-131 is in a large core?
Around 2.7 EBq (about 70 million Ci) in a 3,000 MW core, which is why iodine dominates early accident consequences.
Why does operating time matter only for long-lived nuclides?
Short-lived products reach saturation within a few half-lives; long-lived ones such as Cs-137 keep building up over the whole cycle.
What do the defaults represent?
An illustrative 3,000 MW thermal core after a year at power, iodine-131 (yield 2.89 %, 8.02 days), two days after shutdown.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 8