Fission Rate, U-235 Consumption and Fuel Burn-Up

Fission rate, uranium-235 fissioned and consumed (with capture), energy and average discharge burn-up of a reactor from its thermal power and running time.

Thermal power plant

Inputs

Examples: Illustrative 3000 MWt, 80 t U, 330 daysSmall 100 MWt research core, 1 t, 200 daysPlutonium-239 fuel: 210 MeV, alpha 0.36

Accepted: 1E-6 to 10,000 MW
Accepted: 150 to 220 MeV
Accepted: 0 to 1
Accepted: 230 to 245 kg/kmol
Accepted: 1.157E-5 to 11,574 d
Accepted: 0.001 to 10,000 t

Results

About 1.05 g of U-235 fissions per megawatt-day at 200 MeV per fission, and 1.23 g is consumed with capture. Plutonium bred and fissioned in the fuel carries much of the late-cycle power, so the U-235 figures are an upper bound on what a real core burns.

Fission rate3.1208e+181/s
Fissile nuclide fissioned0.10524kg/d
Fissile nuclide consumed (fission + capture)0.12302kg/d
Consumed per megawatt-day (g)1.2302
Thermal energy produced480.00GWh
Fissile consumed over the period24.604kg
Burn-up over the period20.000GWd/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3000 MWt, 80 t U, 330 days. The inputs, in the units selected above:

InputValue
Reactor thermal power3,000.0 MW
Recoverable energy per fission200.00 MeV
Capture-to-fission ratio of the fissile nuclide (U-235 thermal 0.169)0.16900 -
Molar mass of the fissile nuclide235.04 kg/kmol
Full-power running time330.00 d
Heavy-metal mass in the core (for burn-up)80.000 t

Applying the formula below gives:

ResultValue
Fission rate9.3623e+19 1/s
Fissile nuclide fissioned3.1571 kg/d
Fissile nuclide consumed (fission + capture)3.6906 kg/d
Consumed per megawatt-day (g)1.2302
Thermal energy produced23,760 GWh
Fissile consumed over the period1,217.9 kg
Burn-up over the period12.375 GWd/t

Open this example in the calculator and change any input.

Formula

\(\dot F = \frac{P}{E_R}, \quad \dot m_c = \dot F\frac{M}{N_A}(1 + \alpha), \quad BU = \frac{P t}{m_{HM}}\)

Variables

Symbol Meaning SI unit
\(P\) Reactor thermal power W
\(E_R\) Recoverable energy per fission J
\(\alpha\) Capture-to-fission ratio of the fissile nuclide (U-235 thermal 0.169) -
\(M\) Molar mass of the fissile nuclide kg/kmol
\(t\) Full-power running time s
\(m_{HM}\) Heavy-metal mass in the core (for burn-up) kg
\(\dot F\) Fission rate 1/s
\(\dot m_f\) Fissile nuclide fissioned kg/s
\(\dot m_c\) Fissile nuclide consumed (fission + capture) kg/s
\(g/MWd\) Consumed per megawatt-day (g) -
\(E\) Thermal energy produced J
\(m_c\) Fissile consumed over the period kg
\(BU\) Burn-up over the period J/kg

Method and standards

Fission energy balance.

Where it is used

  • Fuel-cycle planning and burn-up estimates.
  • Teaching reactor energy balances.

Common mistakes

  • Mixing thermal and electrical megawatts.
  • Dividing by the uranium-235 mass instead of the heavy-metal mass for burn-up.

Assumptions and limits

  • Average values; plutonium contribution and spatial burn-up variation not modelled.

References

  • Recoverable fission energy and fuel burn-up arithmetic

Questions and answers

Where do the 200 MeV go?

About 168 MeV as kinetic energy of the fragments, the rest as neutrons, prompt gammas and the beta and gamma decay of fission products; neutrinos (about 10 MeV) escape.

What burn-up do light-water reactors reach?

Typically 40–60 GWd per tonne of heavy metal at discharge.

What do the defaults represent?

An illustrative 3,000 MW thermal core with 80 t of uranium running 330 full-power days.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 4, El-Wakil, Powerplant Technology (McGraw-Hill, 1984), ch. 9-11

Related calculators