FireCADCalc

Fast Neutron Shielding with Removal Cross-Sections

Fast neutron flux behind two shield layers from a point source using removal cross-sections, with the attenuation factor and tenth-value thicknesses.

Thermal power plant

Inputs

Examples: Illustrative 1e12 n/s, 50 cm water + 60 cm concretePolyethylene 30 cm onlyHeavy concrete 1 m + steel 10 cm

Accepted: 1 to 1E+22 1/s
Accepted: 0.01 to 10,000 m
Accepted: 0 to 1,000 cm
Accepted: 0 to 1 1/cm
Accepted: 0 to 1,000 cm
Accepted: 0 to 1 1/cm

Results

Removal theory: fast flux falls as e^(−Σ_R x) in hydrogenous shields, because one collision with hydrogen removes a fast neutron from the penetrating group. Valid for thick shields containing hydrogen; slowed-down neutrons and capture gammas need separate treatment.

Flux with no shield7,957.71/(cm²·s)
Flux behind the shield217.441/(cm²·s)
Attenuation factor0.027324
Tenth-value thickness of layer 119.188cm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1e12 n/s, 50 cm water + 60 cm concrete. The inputs, in the units selected above:

InputValue
Fast neutron source strength (neutrons per second)1.0000e+12 1/s
Distance from source to the point of interest3.0000 m
First layer thickness50.000 cm
First layer removal cross-section (water about 0.10 /cm)0.10300 1/cm
Second layer thickness60.000 cm
Second layer removal cross-section (ordinary concrete about 0.09 /cm)0.089000 1/cm

Applying the formula below gives:

ResultValue
Flux with no shield884,194 1/(cm²·s)
Flux behind the shield24.592 1/(cm²·s)
Attenuation factor2.7813e-05
Tenth-value thickness of layer 122.355 cm
Tenth-value thickness of layer 225.872 cm

Open this example in the calculator and change any input.

Formula

\(\phi = \frac{S}{4\pi r^2}e^{-\Sigma_{R,1}x_1 - \Sigma_{R,2}x_2}, \quad TVL = \frac{\ln 10}{\Sigma_R}\)

Variables

Symbol Meaning SI unit
\(S\) Fast neutron source strength (neutrons per second) 1/s
\(r\) Distance from source to the point of interest m
\(x_1\) First layer thickness m
\(\Sigma_{R,1}\) First layer removal cross-section (water about 0.10 /cm) 1/m
\(x_2\) Second layer thickness m
\(\Sigma_{R,2}\) Second layer removal cross-section (ordinary concrete about 0.09 /cm) 1/m
\(\phi_0\) Flux with no shield 1/(m²·s)
\(\phi\) Flux behind the shield 1/(m²·s)
\(\phi/\phi_0\) Attenuation factor -
\(TVL_1\) Tenth-value thickness of layer 1 m
\(TVL_2\) Tenth-value thickness of layer 2 m

Method and standards

Removal shielding.

Where it is used

  • Reactor and neutron source shield design.
  • Radiation protection planning.

Common mistakes

  • Using removal cross-sections for shields without hydrogen.
  • Ignoring capture gammas produced in the shield.

Assumptions and limits

  • Point source; thick hydrogenous shield; fast group only.

References

  • Removal cross-section method for fast neutron shielding

Questions and answers

Why are hydrogen-rich materials best for neutrons?

A neutron loses on average half its energy in one collision with hydrogen, so water, concrete and polyethylene slow and remove fast neutrons quickly.

What tenth-value thickness does water have?

About 22 cm for fission neutrons with a removal cross-section of 0.103 /cm.

What do the defaults represent?

An illustrative 10¹² n/s fission source 3 m away behind 50 cm of water and 60 cm of concrete.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.