FireCADCalc

Core Average and Peak Linear Heat Rate and Heat Flux

Average and peak linear heat rate, surface heat flux and rod power of a reactor core from thermal power, rod count, active length and peaking factors.

Thermal power plant

Inputs

Examples: Illustrative 3000 MWt, 41000 rodsBWR 3900 MWt, 62000 rods, 3.81 m, 11 mmSmall modular 160 MWt, 6300 rods, 2.0 m

Accepted: 1 to 10,000 MW
Accepted: 80 to 100 %
Accepted: 1 to 1,000,000
Accepted: 0.1 to 10 m
Accepted: 1 to 30 mm
Accepted: 1 to 5
Accepted: 1 to 3

Results

q̄' = γP/(N L); q'_max = F_q q̄'. About 2.6 % of the energy is deposited in the moderator and structure by gammas and neutrons, hence γ ≈ 0.974. F_q is the product of radial, axial and engineering factors.

Average linear heat rate12.368kW/m
Peak linear heat rate27.210kW/m
Average surface heat flux414.41kW/m²
Peak surface heat flux911.71kW/m²
Average rod power24.737kW
Hot rod power37.105kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3000 MWt, 41000 rods. The inputs, in the units selected above:

InputValue
Core thermal power3,000.0 MW
Fraction of power deposited in the fuel (about 0.974)97.400 %
Number of fuel rods41,000 -
Active (heated) length3.6600 m
Rod outer diameter9.5000 mm
Heat flux (total) peaking factor2.2000 -
Enthalpy-rise (hot rod) peaking factor1.5500 -

Applying the formula below gives:

ResultValue
Average linear heat rate19.472 kW/m
Peak linear heat rate42.839 kW/m
Average surface heat flux652.44 kW/m²
Peak surface heat flux1,435.4 kW/m²
Average rod power71.268 kW
Hot rod power110.47 kW

Open this example in the calculator and change any input.

Formula

\(\bar q' = \frac{\gamma P}{N L}, \quad q'_{max} = F_q\bar q', \quad q'' = \frac{q'}{\pi D}\)

Variables

Symbol Meaning SI unit
\(P\) Core thermal power W
\(\gamma\) Fraction of power deposited in the fuel (about 0.974) -
\(N\) Number of fuel rods -
\(L\) Active (heated) length m
\(D\) Rod outer diameter m
\(F_q\) Heat flux (total) peaking factor -
\(F_{\Delta H}\) Enthalpy-rise (hot rod) peaking factor -
\(\bar q'\) Average linear heat rate W/m
\(q'_{max}\) Peak linear heat rate W/m
\(\bar q''\) Average surface heat flux W/m²
\(q''_{max}\) Peak surface heat flux W/m²
\(\bar P_{rod}\) Average rod power W
\(P_{hot}\) Hot rod power W

Method and standards

Core averages and peaking factors.

Where it is used

  • Core design and fuel performance limits.
  • Technical specification checks.

Common mistakes

  • Forgetting the fraction of energy deposited outside the fuel.
  • Using the fuel stack length including plenums.

Assumptions and limits

  • Uniform rod count and length.

References

  • Core power distribution averages and peaking factors

Questions and answers

What linear heat rates do light-water reactors run at?

About 15–20 kW/m on average and up to about 40–45 kW/m at the peak.

What is the difference between F_q and F_ΔH?

F_q is the local peak heat flux over the average; F_ΔH is the hot rod's whole-length power over the average rod, which sets its coolant enthalpy rise.

What do the defaults represent?

An illustrative 3,000 MW thermal core with 41,000 rods, 3.66 m active length, 9.5 mm rods, F_q 2.2 and F_ΔH 1.55.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 1 and 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.