Worked example
Example: Illustrative 3000 MWt, 41000 rods. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Core thermal power | 3,000.0 MW |
| Fraction of power deposited in the fuel (about 0.974) | 97.400 % |
| Number of fuel rods | 41,000 - |
| Active (heated) length | 3.6600 m |
| Rod outer diameter | 9.5000 mm |
| Heat flux (total) peaking factor | 2.2000 - |
| Enthalpy-rise (hot rod) peaking factor | 1.5500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Average linear heat rate | 19.472 kW/m |
| Peak linear heat rate | 42.839 kW/m |
| Average surface heat flux | 652.44 kW/m² |
| Peak surface heat flux | 1,435.4 kW/m² |
| Average rod power | 71.268 kW |
| Hot rod power | 110.47 kW |
Open this example in the calculator and change any input.
Formula
\(\bar q' = \frac{\gamma P}{N L}, \quad q'_{max} = F_q\bar q', \quad q'' = \frac{q'}{\pi D}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Core thermal power | W |
| \(\gamma\) | Fraction of power deposited in the fuel (about 0.974) | - |
| \(N\) | Number of fuel rods | - |
| \(L\) | Active (heated) length | m |
| \(D\) | Rod outer diameter | m |
| \(F_q\) | Heat flux (total) peaking factor | - |
| \(F_{\Delta H}\) | Enthalpy-rise (hot rod) peaking factor | - |
| \(\bar q'\) | Average linear heat rate | W/m |
| \(q'_{max}\) | Peak linear heat rate | W/m |
| \(\bar q''\) | Average surface heat flux | W/m² |
| \(q''_{max}\) | Peak surface heat flux | W/m² |
| \(\bar P_{rod}\) | Average rod power | W |
| \(P_{hot}\) | Hot rod power | W |
Method and standards
Core averages and peaking factors.
Where it is used
- Core design and fuel performance limits.
- Technical specification checks.
Common mistakes
- Forgetting the fraction of energy deposited outside the fuel.
- Using the fuel stack length including plenums.
Assumptions and limits
- Uniform rod count and length.
References
- Core power distribution averages and peaking factors
Questions and answers
What linear heat rates do light-water reactors run at?
About 15–20 kW/m on average and up to about 40–45 kW/m at the peak.
What is the difference between F_q and F_ΔH?
F_q is the local peak heat flux over the average; F_ΔH is the hot rod's whole-length power over the average rod, which sets its coolant enthalpy rise.
What do the defaults represent?
An illustrative 3,000 MW thermal core with 41,000 rods, 3.66 m active length, 9.5 mm rods, F_q 2.2 and F_ΔH 1.55.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 1 and 3