Containment Pressure after a Loss-of-Coolant Accident

Equilibrium containment pressure and temperature after the primary coolant blows down into the containment air, from an adiabatic energy and volume balance.

Thermal power plant

Inputs

Examples: Illustrative 250 t into 60000 m3Large dry containment 75000 m3, 300 tBWR drywell-style small volume 8000 m3, 50 t at 7 MPa

Accepted: 0.001 to 10,000 t
Accepted: 0.1 to 30 MPa
Accepted: 6.85 to 366.85 °C
Accepted: 1 to 10,000,000 m³
Accepted: 50 to 500 kPa
Accepted: -23.15 to 76.85 °C
Accepted: 0.28 to 0.295 kJ/(kg·K)
Accepted: 0.6 to 0.8 kJ/(kg·K)

Results

Adiabatic, rigid containment with no heat sinks or sprays: the internal energy of coolant and air is conserved and the water (specific volume V/m_w) ends as a saturated mixture at T. Real peaks are lower because walls and structures absorb heat; licensing analyses use transient codes. Water and steam properties from IAPWS-IF97.

Final equilibrium temperature133.65°C
Final containment pressure (absolute)435.15kPa
Steam partial pressure301.06kPa
Air partial pressure134.10kPa
Fraction of the released water as steam41.301%
Mass of air85.913t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 t into 60000 m3. The inputs, in the units selected above:

InputValue
Mass of coolant released250.00 t
Coolant pressure before release15.500 MPa
Coolant temperature before release310.00 °C
Containment free volume60,000 m³
Initial containment air pressure101.33 kPa
Initial containment air temperature40.000 °C
Gas constant of air0.28705 kJ/(kg·K)
Specific heat of air at constant volume0.71800 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Final equilibrium temperature133.89 °C
Final containment pressure (absolute)435.32 kPa
Steam partial pressure303.26 kPa
Air partial pressure132.06 kPa
Fraction of the released water as steam39.914 %
Mass of air67.633 t

Open this example in the calculator and change any input.

Formula

\(m_wu_{w,0} + m_ac_{v,a}T_{a0} = m_w\left[u_f + x(u_g - u_f)\right]_T + m_ac_{v,a}T, \quad x = \frac{V/m_w - v_f}{v_g - v_f}, \quad p = p_{sat}(T) + \frac{m_aR_aT}{V - m_w(1 - x)v_f}\)

Variables

Symbol Meaning SI unit
\(m_w\) Mass of coolant released kg
\(p_w\) Coolant pressure before release Pa
\(T_w\) Coolant temperature before release K
\(V\) Containment free volume m³
\(p_{a0}\) Initial containment air pressure Pa
\(T_{a0}\) Initial containment air temperature K
\(R_a\) Gas constant of air J/(kg·K)
\(c_{v,a}\) Specific heat of air at constant volume J/(kg·K)
\(T\) Final equilibrium temperature K
\(p\) Final containment pressure (absolute) Pa
\(p_s\) Steam partial pressure Pa
\(p_a\) Air partial pressure Pa
\(x\) Fraction of the released water as steam -
\(m_a\) Mass of air kg

Method and standards

Containment energy balance.

Where it is used

  • Scoping containment design pressure.
  • Teaching accident analysis.

Common mistakes

  • Adding the steam pressure to the initial air pressure without the temperature rise.
  • Forgetting the volume taken by liquid water.

Assumptions and limits

  • Adiabatic and rigid; uniform final state; dry initial air.

References

  • Adiabatic energy and volume balance of a containment blowdown

Questions and answers

Why does the containment end at only a few bar?

The coolant flashes and its energy is shared with a large volume of air; a large dry PWR containment ends near 0.3–0.5 MPa absolute.

Why is this result higher than the real peak?

Walls, steel and concrete absorb much of the energy within minutes, and sprays and fan coolers condense steam.

What do the defaults represent?

An illustrative release of 250 t of coolant at 15.5 MPa and 310 °C into 60,000 m³ of air at 101 kPa and 40 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.