Worked example
Example: Illustrative 250 t into 60000 m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mass of coolant released | 250.00 t |
| Coolant pressure before release | 15.500 MPa |
| Coolant temperature before release | 310.00 °C |
| Containment free volume | 60,000 m³ |
| Initial containment air pressure | 101.33 kPa |
| Initial containment air temperature | 40.000 °C |
| Gas constant of air | 0.28705 kJ/(kg·K) |
| Specific heat of air at constant volume | 0.71800 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Final equilibrium temperature | 133.89 °C |
| Final containment pressure (absolute) | 435.32 kPa |
| Steam partial pressure | 303.26 kPa |
| Air partial pressure | 132.06 kPa |
| Fraction of the released water as steam | 39.914 % |
| Mass of air | 67.633 t |
Open this example in the calculator and change any input.
Formula
\(m_wu_{w,0} + m_ac_{v,a}T_{a0} = m_w\left[u_f + x(u_g - u_f)\right]_T + m_ac_{v,a}T, \quad x = \frac{V/m_w - v_f}{v_g - v_f}, \quad p = p_{sat}(T) + \frac{m_aR_aT}{V - m_w(1 - x)v_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_w\) | Mass of coolant released | kg |
| \(p_w\) | Coolant pressure before release | Pa |
| \(T_w\) | Coolant temperature before release | K |
| \(V\) | Containment free volume | m³ |
| \(p_{a0}\) | Initial containment air pressure | Pa |
| \(T_{a0}\) | Initial containment air temperature | K |
| \(R_a\) | Gas constant of air | J/(kg·K) |
| \(c_{v,a}\) | Specific heat of air at constant volume | J/(kg·K) |
| \(T\) | Final equilibrium temperature | K |
| \(p\) | Final containment pressure (absolute) | Pa |
| \(p_s\) | Steam partial pressure | Pa |
| \(p_a\) | Air partial pressure | Pa |
| \(x\) | Fraction of the released water as steam | - |
| \(m_a\) | Mass of air | kg |
Method and standards
Containment energy balance.
Where it is used
- Scoping containment design pressure.
- Teaching accident analysis.
Common mistakes
- Adding the steam pressure to the initial air pressure without the temperature rise.
- Forgetting the volume taken by liquid water.
Assumptions and limits
- Adiabatic and rigid; uniform final state; dry initial air.
References
- Adiabatic energy and volume balance of a containment blowdown
Questions and answers
Why does the containment end at only a few bar?
The coolant flashes and its energy is shared with a large volume of air; a large dry PWR containment ends near 0.3–0.5 MPa absolute.
Why is this result higher than the real peak?
Walls, steel and concrete absorb much of the energy within minutes, and sprays and fan coolers condense steam.
What do the defaults represent?
An illustrative release of 250 t of coolant at 15.5 MPa and 310 °C into 60,000 m³ of air at 101 kPa and 40 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 7