Flue Gas Cooling by Water Spray (Evaporative Quench)

Water to spray into flue gas to cool it to a target temperature, with full evaporation (IF97 vapour enthalpy at its partial pressure), and the water dew point of the cooled gas.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Dust collector (ESP, bag filter, cyclone)

Inputs

Examples: 200 to 150 °CQuench 350 to 180 °CGas-fired 160 to 80 °C

From the flue gas analysis; about 0.06 to 0.10 for coal, 0.10 to 0.12 for oil, 0.18 for natural gas, 0.20 to 0.30 for wet biomass.
About 29.5 kg/kmol for coal flue gas, 28 for natural gas flue gas.

Results

Allow residence time and fine atomisation for the droplets to evaporate fully.

The outlet is only 17 K above the water dew point: droplets may not evaporate and dust can cake on filters. Most plants keep 20–30 K or more.

Water dew point only; an acid (SO₃) dew point, if the gas carries sulphur, is higher.

Heat removed from the gas1,222.2kW
Spray water1,745.0kg/h
Water per kg of gas34.901g/kg
Water vapour partial pressure at the outlet22.514kPa
Water dew point of the cooled gas62.640°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 to 150 °C. The inputs, in the units selected above:

InputValue
Flue gas flow100.00 t/h
Gas specific heat1.1000 kJ/(kg·K)
Gas in200.00 °C
Gas out (target)150.00 °C
Spray water temperature30.000 °C
Water vapour in the inlet gas, volume fraction (wet)10.000 %
Molar mass of the inlet gas (wet)29.500 kg/kmol
Gas pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Heat removed from the gas1,527.8 kW
Spray water2,070.0 kg/h
Water per kg of gas20.700 g/kg
Water vapour partial pressure at the outlet13.122 kPa
Water dew point of the cooled gas51.226 °C

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_g c_{p,g}(T_1 - T_2), \quad \dot m_w = \frac{\dot Q}{h_v(p_{v,2}, T_2) - h_l(T_w)}\)

\(p_{v,2} = p\,\frac{y_w \dot m_g/M_g + \dot m_w/M_{H_2O}}{\dot m_g/M_g + \dot m_w/M_{H_2O}}, \quad T_{dp} = T_{sat}(p_{v,2})\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Flue gas flow kg/s
\(c_{p,g}\) Gas specific heat J/(kg·K)
\(T_1\) Gas in K
\(T_2\) Gas out (target) K
\(T_w\) Spray water temperature K
\(y_w\) Water vapour in the inlet gas, volume fraction (wet) -
\(M_g\) Molar mass of the inlet gas (wet) kg/kmol
\(M_{H_2O}\) Molar mass of water, 18.015 kg/kmol
\(p\) Gas pressure, absolute Pa
\(\dot Q\) Heat removed from the gas W
\(\dot m_w\) Spray water kg/s
\(\dot m_w/\dot m_g\) Water per kg of gas kg/kg
\(p_{v,2}\) Water vapour partial pressure at the outlet Pa
\(T_{dp}\) Water dew point of the cooled gas K
\(T_{sat}\) Saturation temperature of water (IF97) K
\(h_v\) Water vapour enthalpy at its partial pressure and the outlet temperature (IF97) J/kg
\(h_l\) Liquid water enthalpy at the spray temperature (IF97) J/kg

Method and standards

Energy balance: the heat the gas gives up evaporates the spray water and heats the vapour to the outlet temperature. The vapour enthalpy is taken from IAPWS-IF97 at the outlet temperature and at the vapour's own partial pressure in the cooled gas, which depends on the water sprayed, so the balance is solved by iteration. The water dew point is the saturation temperature at that partial pressure.

Where it is used

  • Bag filter and ESP protection.
  • Gas conditioning.

Common mistakes

  • Ignoring the latent heat.
  • Cooling close to the dew point: the last droplets need a long time to evaporate.

Assumptions and limits

  • Complete evaporation; the gas specific heat is a mean value and the inlet gas composition is given by its water vapour fraction and molar mass.
  • A note appears when the outlet is less than 20 K above the water dew point; the calculation fails when the outlet would be saturated.
  • The acid (SO₃) dew point, if the gas carries sulphur, is higher than the water dew point and is not computed here.

References

  • Energy balance with IAPWS-IF97 enthalpies (water at inlet temperature to vapour at the gas outlet temperature)

Questions and answers

Why cool with water rather than air?

Water's latent heat cools the gas with far less added volume than dilution air.

Limit?

The outlet must stay well above the water dew point, which the calculator gives (about 51 °C for 100 t/h of coal flue gas cooled from 200 to 150 °C), or wet dust cakes on filters.

Droplet size?

Fine atomisation and enough residence time are needed for complete evaporation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.