Worked example
Example: 200 to 150 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flue gas flow | 100.00 t/h |
| Gas specific heat | 1.1000 kJ/(kg·K) |
| Gas in | 200.00 °C |
| Gas out (target) | 150.00 °C |
| Spray water temperature | 30.000 °C |
| Water vapour in the inlet gas, volume fraction (wet) | 10.000 % |
| Molar mass of the inlet gas (wet) | 29.500 kg/kmol |
| Gas pressure (absolute) | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat removed from the gas | 1,527.8 kW |
| Spray water | 2,070.0 kg/h |
| Water per kg of gas | 20.700 g/kg |
| Water vapour partial pressure at the outlet | 13.122 kPa |
| Water dew point of the cooled gas | 51.226 °C |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_g c_{p,g}(T_1 - T_2), \quad \dot m_w = \frac{\dot Q}{h_v(p_{v,2}, T_2) - h_l(T_w)}\)
\(p_{v,2} = p\,\frac{y_w \dot m_g/M_g + \dot m_w/M_{H_2O}}{\dot m_g/M_g + \dot m_w/M_{H_2O}}, \quad T_{dp} = T_{sat}(p_{v,2})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Flue gas flow | kg/s |
| \(c_{p,g}\) | Gas specific heat | J/(kg·K) |
| \(T_1\) | Gas in | K |
| \(T_2\) | Gas out (target) | K |
| \(T_w\) | Spray water temperature | K |
| \(y_w\) | Water vapour in the inlet gas, volume fraction (wet) | - |
| \(M_g\) | Molar mass of the inlet gas (wet) | kg/kmol |
| \(M_{H_2O}\) | Molar mass of water, 18.015 | kg/kmol |
| \(p\) | Gas pressure, absolute | Pa |
| \(\dot Q\) | Heat removed from the gas | W |
| \(\dot m_w\) | Spray water | kg/s |
| \(\dot m_w/\dot m_g\) | Water per kg of gas | kg/kg |
| \(p_{v,2}\) | Water vapour partial pressure at the outlet | Pa |
| \(T_{dp}\) | Water dew point of the cooled gas | K |
| \(T_{sat}\) | Saturation temperature of water (IF97) | K |
| \(h_v\) | Water vapour enthalpy at its partial pressure and the outlet temperature (IF97) | J/kg |
| \(h_l\) | Liquid water enthalpy at the spray temperature (IF97) | J/kg |
Method and standards
Energy balance: the heat the gas gives up evaporates the spray water and heats the vapour to the outlet temperature. The vapour enthalpy is taken from IAPWS-IF97 at the outlet temperature and at the vapour's own partial pressure in the cooled gas, which depends on the water sprayed, so the balance is solved by iteration. The water dew point is the saturation temperature at that partial pressure.
Where it is used
- Bag filter and ESP protection.
- Gas conditioning.
Common mistakes
- Ignoring the latent heat.
- Cooling close to the dew point: the last droplets need a long time to evaporate.
Assumptions and limits
- Complete evaporation; the gas specific heat is a mean value and the inlet gas composition is given by its water vapour fraction and molar mass.
- A note appears when the outlet is less than 20 K above the water dew point; the calculation fails when the outlet would be saturated.
- The acid (SO₃) dew point, if the gas carries sulphur, is higher than the water dew point and is not computed here.
References
- Energy balance with IAPWS-IF97 enthalpies (water at inlet temperature to vapour at the gas outlet temperature)
Questions and answers
Why cool with water rather than air?
Water's latent heat cools the gas with far less added volume than dilution air.
Limit?
The outlet must stay well above the water dew point, which the calculator gives (about 51 °C for 100 t/h of coal flue gas cooled from 200 to 150 °C), or wet dust cakes on filters.
Droplet size?
Fine atomisation and enough residence time are needed for complete evaporation.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.