Worked example
Example: 500 mg/Nm3 at 6 % O2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pollutant concentration (dry, 0 °C, 1 atm) | 500.00 mg/Nm³ |
| Oxygen in dry flue gas | 6.0000 % |
| Dry F-factor (dscm per GJ at 20 °C) | 264.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Concentration at 20 °C | 465.89 mg/m³ |
| Emission rate | 172.52 g/GJ |
Open this example in the calculator and change any input.
Formula
\(C_{20} = C_d \frac{273.15}{293.15}, \quad E = C_{20} F_d \frac{20.9}{20.9 - \%O_{2,d}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_d\) | Pollutant concentration (dry, 0 °C, 1 atm) | kg/m³ |
| \(O_{2,d}\) | Oxygen in dry flue gas | - |
| \(F_d\) | Dry F-factor (dscm per GJ at 20 °C) | - |
| \(C_{20}\) | Concentration at 20 °C | kg/m³ |
| \(E\) | Emission rate | kg/J |
Method and standards
US EPA Method 19.
Where it is used
- Emission reports per heat input.
- Comparing permits in different units.
Common mistakes
- Wet O₂ with dry concentration.
Assumptions and limits
- Dry basis throughout.
- EPA F-factors are per unit of gross (higher) calorific value, so the emission rate is per GJ of HHV.
- The F-factor is entered in dscm per GJ at 20 °C in every unit system.
References
- US EPA Method 19 Eq. 19-1
- E = C_d F_d 20.9/(20.9 − %O₂d); 0 °C to 20 °C by ideal gas
Questions and answers
Why g/GJ?
It compares boilers and fuels independent of dilution and size.
Why convert 0 °C to 20 °C?
Method 19 F-factors use 20 °C; a normal cubic metre at 0 °C holds more gas.
lb/MMBtu?
Divide g/GJ by 429.9 (453.59 g/lb over 1.0551 GJ/MMBtu), or choose an FPS display for the output. The F-factor input is in dscm/GJ; convert EPA table values in dscf/MMBtu by multiplying by 0.02684.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.