FireCADCalc

CO₂ Emission Factor of a Fuel

CO₂ per kg of fuel and per GJ on gross and net calorific value from the carbon content, with hourly and annual CO₂ for a firing rate.

Thermal power plantSugar mill and cogenerationChemical and fertiliserThermic fluid heatingPulp and paperIAPWS-IF97 (water and steam)BoilerBurner and furnaceStack and chimney

Inputs

Examples: Indian coal, 18.6 MJ/kg, 50 t/h, 8 000 hFuel oil, 42.5 MJ/kg, 2 t/h, 7 000 h, 99 % oxidisedNatural gas (methane), 55.5 MJ/kg

IPCC 2006 default is 100 %. Lower it only for measured unburned carbon in ash.

Results

CO₂ per kg of fuel2.7432kg/kg
CO₂ per unit of heat, on NCV (IPCC basis)54.831kg/GJ
CO₂ per unit of heat, on GCV49.415kg/GJ
Net calorific value50,030kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal, 18.6 MJ/kg, 50 t/h, 8 000 h. The inputs, in the units selected above:

InputValue
Carbon, as fired, by mass45.000 %
Hydrogen, as fired, by mass3.5000 %
Moisture, as fired, by mass10.000 %
Gross calorific value, as fired18,600 kJ/kg
Fraction of carbon oxidised100.00 %
Fuel firing rate (0 = skip)50,000 kg/h
Operating hours per year8,000.0 h

Applying the formula below gives:

ResultValue
CO₂ per kg of fuel1.6488 kg/kg
CO₂ per unit of heat, on NCV (IPCC basis)93.725 kg/GJ
CO₂ per unit of heat, on GCV88.647 kg/GJ
Net calorific value17,592 kJ/kg
CO₂ emitted82.441 t/h
CO₂ per year659,530 t

Open this example in the calculator and change any input.

Formula

\(e_m = C \cdot \frac{M_{CO_2}}{M_C} \cdot f_{ox} = 3.664\;C\,f_{ox}\)

\(NCV = GCV - h_{fg,25}\left(\frac{M_{H_2O}}{M_{H_2}}H + M\right) \qquad e_{NCV} = \frac{e_m}{NCV} \qquad e_{GCV} = \frac{e_m}{GCV}\)

\(\dot m_{CO_2} = \dot m_f\,e_m \qquad m_{CO_2} = \dot m_{CO_2}\,t_{op}\)

Variables

Symbol Meaning SI unit
\(C\) carbon in the fuel as fired, by mass –
\(H\) hydrogen in the fuel as fired –
\(M\) moisture in the fuel as fired –
\(GCV\) gross calorific value as fired J/kg
\(f_{ox}\) fraction of carbon oxidised –
\(\dot m_f\) fuel firing rate kg/s
\(t_{op}\) operating hours per year s
\(e_m\) CO₂ per kg of fuel kg/kg
\(e_{NCV}\) CO₂ per unit of heat on NCV kg/J
\(e_{GCV}\) CO₂ per unit of heat on GCV kg/J
\(NCV\) net calorific value J/kg
\(\dot m_{CO_2}\) CO₂ emitted kg/s
\(m_{CO_2}\) CO₂ per year kg
\(M_{CO_2}\), \(M_C\), \(M_{H_2O}\), \(M_{H_2}\) molar masses (44.009, 12.011, 18.015, 2.016) kg/kmol
\(h_{fg,25}\) latent heat of water at 25 °C (2 441.7 kJ/kg, IF97) J/kg

Method and standards

The carbon-content method of the IPCC 2006 Guidelines (Vol. 2, Energy): CO₂ = carbon × 44/12 × fraction oxidised, here with exact IUPAC molar masses (44.009/12.011). The IPCC default fraction oxidised is 1. The net calorific value is the gross value less the latent heat at 25 °C of the water formed from hydrogen and the fuel moisture, the ASME PTC 4 convention; the latent heat comes from FireCAD's IAPWS-IF97.

Where it is used

  • Carbon accounting of boilers and furnaces.
  • Comparing fuels by CO2 per GJ.
  • Emission reports and carbon cost estimates.

Common mistakes

  • Using NCV in one place and GCV in another.
  • Using a default factor when the fuel analysis is available.
  • Counting biomass CO2 the same way as fossil CO2 where rules treat it differently.

Assumptions and limits

  • Carbon content as fired, on the same moisture basis as the calorific value and the firing rate.
  • All carbon that is oxidised ends as CO₂; carbonates in the ash and limestone used for desulphurisation add CO₂ not counted here.
  • The net value is the PTC 4 style deduction (latent heat at 25 °C, no constant-volume oxygen and nitrogen correction). Net values measured to ISO 1928 or used in IPCC tables may differ slightly, so \(e_{NCV}\) depends on this convention.
  • For natural gas enter the analysis by mass (methane: 74.9 % carbon, 25.1 % hydrogen).

References

  • IPCC 2006 Guidelines Vol. 2 Ch. 1–2 (carbon-content method)
  • IUPAC atomic weights
  • IAPWS R7-97(2012) IF97 (latent heat)

Questions and answers

How much CO₂ does 1 kg of coal produce?

Each kg of carbon becomes 44.009/12.011 = 3.664 kg of CO₂. An Indian coal with 45 % carbon gives 1.65 kg CO₂ per kg, or 93.7 kg per GJ on its net calorific value.

Why per GJ on NCV?

The IPCC 2006 Guidelines and most national inventories state emission factors per unit of net calorific value. Indian and US plant data are often on GCV; the calculator gives both.

Is biomass CO₂ counted?

The calculator gives the CO₂ physically released. Under IPCC rules CO₂ from sustainably grown biomass such as bagasse is reported separately and not counted in the energy-sector total.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.