Worked example
Example: 100 KLPD ZLD. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plant capacity (absolute alcohol) | 100.00 kL/d |
| Distillation steam | 2.3000 kg/L |
| Dehydration steam | 0.40000 kg/L |
| Spent wash evaporation steam | 2.0000 kg/L |
| Other users (liquefaction, CIP, tracing) | 0.30000 kg/L |
| Design margin | 15.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total specific steam | 5.0000 kg/L |
| Average steam demand | 20.833 t/h |
| Boiler rating with margin | 23.958 t/h |
Open this example in the calculator and change any input.
Formula
\(s_t = s_d + s_h + s_e + s_o, \quad \dot m_b = \dot V_e s_t (1 + k)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_e\) | Plant capacity (absolute alcohol) | m³/s |
| \(s_d\) | Distillation steam | kg/m³ |
| \(s_h\) | Dehydration steam | kg/m³ |
| \(s_e\) | Spent wash evaporation steam | kg/m³ |
| \(s_o\) | Other users (liquefaction, CIP, tracing) | kg/m³ |
| \(k\) | Design margin | - |
| \(s_t\) | Total specific steam | kg/m³ |
| \(\dot m_s\) | Average steam demand | kg/s |
| \(\dot m_b\) | Boiler rating with margin | kg/s |
Method and standards
Steam balance.
Where it is used
- New distillery and expansion boilers.
- FireCAD boiler enquiries.
Common mistakes
- Bulk litres used.
Assumptions and limits
- Average steady load.
- Specific steam figures are by mass with no pressure or enthalpy basis; the boiler rating in t/h holds only at the steam conditions those figures assume. A boiler at higher pressure feeding the process through a PRDS and desuperheater delivers a different mass.
- The default specific steam figures (2.3 + 0.4 + 2.0 + 0.3 = 5.0 kg/L) are starting values without a particular source; use your plant's or the supplier's figures.
- Specific steam is entered and shown in kg/L in every unit system.
References
- Steam balance on specific consumptions (kg per litre of alcohol)
Questions and answers
How big a boiler for 100 KLPD?
With the defaults, about 21 t/h average and 24 t/h with margin; your specific steam decides.
Biggest steam user?
Distillation, then spent wash evaporation for ZLD plants.
Turbine?
A back-pressure turbine between boiler and process makes the plant's power from the same steam.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.