FireCADCalc

Tolerance Stack-Up: Worst Case and RSS

Nominal gap and its variation from up to six dimensions in a chain, by worst case (sum of tolerances) and statistical RSS (root sum of squares).

Inputs

Examples: Housing and three partsSix-part chain

Dimension 1

Dimension 2

Dimension 3

Dimension 4

Dimension 5

Dimension 6

Results

RSS assumes independent, centred, normally distributed dimensions; worst case is guaranteed.

Nominal gap1.0000mm
Worst-case variation0.17000mm
RSS variation0.092195mm
Worst-case minimum gap0.83000mm
Worst-case maximum gap1.1700mm
Statistical (RSS) minimum gap0.90780mm
Statistical (RSS) maximum gap1.0922mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Housing and three parts. The inputs, in the units selected above:

InputValue
Dimension 1: direction (+1 adds, −1 subtracts, 0 unused)+1: adds to the gap
Dimension 1: nominal100.00 mm
Dimension 1: ± tolerance0.10000 mm
Dimension 2: direction (+1 adds, −1 subtracts, 0 unused)−1: subtracts from the gap
Dimension 2: nominal40.000 mm
Dimension 2: ± tolerance0.050000 mm
Dimension 3: direction (+1 adds, −1 subtracts, 0 unused)−1: subtracts from the gap
Dimension 3: nominal30.000 mm
Dimension 3: ± tolerance0.050000 mm
Dimension 4: direction (+1 adds, −1 subtracts, 0 unused)−1: subtracts from the gap
Dimension 4: nominal29.500 mm
Dimension 4: ± tolerance0.050000 mm
Dimension 5: direction (+1 adds, −1 subtracts, 0 unused)0: not used
Dimension 5: nominal0 mm
Dimension 5: ± tolerance0 mm
Dimension 6: direction (+1 adds, −1 subtracts, 0 unused)0: not used
Dimension 6: nominal0 mm
Dimension 6: ± tolerance0 mm

Applying the formula below gives:

ResultValue
Nominal gap0.50000 mm
Worst-case variation0.25000 mm
RSS variation0.13229 mm
Worst-case minimum gap0.25000 mm
Worst-case maximum gap0.75000 mm
Statistical (RSS) minimum gap0.36771 mm
Statistical (RSS) maximum gap0.63229 mm

Open this example in the calculator and change any input.

Formula

\(G = \sum s_i d_i, \quad t_{WC} = \sum t_i, \quad t_{RSS} = \sqrt{\sum t_i^2}, \quad G_{min,max} = G \mp t_{WC}, \quad G_{min,max,RSS} = G \mp t_{RSS}\)

Variables

Symbol Meaning SI unit
\(s_{1}\) Dimension 1: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{1}\) Dimension 1: nominal m
\(t_{1}\) Dimension 1: ± tolerance m
\(s_{2}\) Dimension 2: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{2}\) Dimension 2: nominal m
\(t_{2}\) Dimension 2: ± tolerance m
\(s_{3}\) Dimension 3: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{3}\) Dimension 3: nominal m
\(t_{3}\) Dimension 3: ± tolerance m
\(s_{4}\) Dimension 4: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{4}\) Dimension 4: nominal m
\(t_{4}\) Dimension 4: ± tolerance m
\(s_{5}\) Dimension 5: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{5}\) Dimension 5: nominal m
\(t_{5}\) Dimension 5: ± tolerance m
\(s_{6}\) Dimension 6: direction (+1 adds, −1 subtracts, 0 unused) -
\(d_{6}\) Dimension 6: nominal m
\(t_{6}\) Dimension 6: ± tolerance m
\(G\) Nominal gap m
\(\pm t_{WC}\) Worst-case variation m
\(\pm t_{RSS}\) RSS variation m
\(G_{min}\) Worst-case minimum gap m
\(G_{max}\) Worst-case maximum gap m
\(G_{min,RSS}\) Statistical (RSS) minimum gap m
\(G_{max,RSS}\) Statistical (RSS) maximum gap m

Method and standards

Linear stack.

Where it is used

  • Assembly design and gap checks.
  • Bearing and seal housings.

Common mistakes

  • Asymmetric tolerances unconverted.
  • RSS on a few parts.

Assumptions and limits

  • Each direction is chosen as +1, −1 or 0; other values are rejected. A negative minimum gap (interference) is flagged.

  • Linear one-dimensional chain.

References

  • Worst case Σt_i; statistical RSS √Σt_i² (tolerance analysis practice)

Questions and answers

A 100 ± 0.1 housing with three parts 40, 30 and 29.5 ± 0.05?

Gap 0.5 mm ± 0.25 worst case, ± 0.132 RSS.

Which to use?

Worst case for safety-critical fits; RSS for high-volume parts with process control.

Asymmetric tolerances?

Convert to a mean size and an equal ± tolerance first.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.