Worked example
Example: 50 kg iron in 20 s, 300 mm sprue, 1:2:2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Poured mass (casting + gating) | 50.000 kg |
| Liquid metal density | 7,000.0 kg/m³ |
| Pouring time | 20.000 s |
| Effective sprue height | 0.30000 m |
| Efficiency (discharge) factor | 0.80000 - |
| Runner area ratio to choke | 2.0000 - |
| Total gate area ratio to choke | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Choke area | 184.04 mm² |
| Round choke diameter | 15.308 mm |
| Runner area | 368.08 mm² |
| Total gate area | 368.08 mm² |
| Velocity at the choke | 1.9406 m/s |
Open this example in the calculator and change any input.
Formula
\(A_c = \frac{W}{\rho tc\sqrt{2gh}}, \quad A_r = r_rA_c, \quad A_g = r_gA_c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Poured mass (casting + gating) | kg |
| \(\rho\) | Liquid metal density | kg/m³ |
| \(t\) | Pouring time | s |
| \(h\) | Effective sprue height | m |
| \(c\) | Efficiency (discharge) factor | - |
| \(r_r\) | Runner area ratio to choke | - |
| \(r_g\) | Total gate area ratio to choke | - |
| \(A_c\) | Choke area | m² |
| \(d_c\) | Round choke diameter | m |
| \(A_r\) | Runner area | m² |
| \(A_g\) | Total gate area | m² |
| \(v_c\) | Velocity at the choke | m/s |
Method and standards
Bernoulli at the choke.
Where it is used
- Foundry gating design.
- Teaching and exam problems.
Common mistakes
- Using total sprue height for bottom gating.
- Ignoring friction (c).
Assumptions and limits
- Steady flow; constant head.
- The choke velocity is not checked against the critical gate velocity for surface turbulence (Campbell gives about 0.5 m/s for most liquid metals at the gate): gates are normally enlarged so the metal enters slowly.
References
- Bernoulli flow through the choke A_c = W/(ρtc√(2gh)) (Campbell, Castings, 2nd ed.; Rao, Manufacturing Technology: Foundry)
Questions and answers
Why control pouring time?
Too slow and the metal freezes before filling (cold shuts); too fast and turbulence entrains sand and oxide.
What is the choke?
The smallest section of the gating system; it controls the flow rate.
What do the defaults represent?
A 50 kg steel or iron casting poured in 20 s through a 300 mm sprue with a 1:2:2 gating ratio.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.