Worked example
Example: Running fit. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hole upper limit | 50.025 mm |
| Hole lower limit | 50.000 mm |
| Shaft upper limit | 49.975 mm |
| Shaft lower limit | 49.950 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Maximum clearance H_max − S_min | 75.000 µm |
| Minimum clearance H_min − S_max (negative: interference) | 25.000 µm |
| Fit (1 clearance, 2 transition, 3 interference) | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(C_{max} = H_{max} - S_{min}, \quad C_{min} = H_{min} - S_{max}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H_{max}\) | Hole upper limit | m |
| \(H_{min}\) | Hole lower limit | m |
| \(S_{max}\) | Shaft upper limit | m |
| \(S_{min}\) | Shaft lower limit | m |
| \(C_{max}\) | Maximum clearance H_max − S_min | m |
| \(C_{min}\) | Minimum clearance H_min − S_max (negative: interference) | m |
| \(\text{type}\) | Fit (1 clearance, 2 transition, 3 interference) | - |
Method and standards
Limits.
Where it is used
- Bearing housings, couplings and bushes.
- Drawing checks.
Common mistakes
- Mixing deviations with limits.
- Ignoring temperature differences.
Assumptions and limits
- Measured at the same temperature.
References
- Limits and fits: C_max = H_max − S_min
- C_min = H_min − S_max (ISO 286 terminology)
Questions and answers
Ø50 H7 hole (+0/+25 µm) with an f7-like shaft (−25/−50 µm)?
Clearance 25 to 75 µm: a running fit.
Transition fit?
Minimum clearance negative and maximum positive: it may slide or need light pressing.
Interference?
Then use the interference fit calculator for the pressure.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.