FireCADCalc

Weber, Bond, Capillary and Ohnesorge Numbers

Weber, Bond (Eötvös), capillary and Ohnesorge numbers and the capillary length, which show when surface tension matters against inertia, gravity and viscosity.

Inputs

Examples: Illustrative 2 mm water drop at 2 m/sInkjet drop of inkAir bubble in oil

Accepted: 0.1 to 25,000 kg/m³
Accepted: 0.01 to 25,000 kg/m³
Accepted: 0.001 to 100,000 mPa·s
Accepted: 0.1 to 2,000 mN/m
Accepted: 0 to 1,000 m/s
Accepted: 1E-4 to 10,000 mm

Results

Surface tension competes with inertia (Weber number), gravity (Bond or Eötvös number) and viscosity (capillary number). Drops break up in a gas stream above We ≈ 12; bubbles and drops are nearly spherical for Bo ≪ 1 and deform for Bo > 1; the capillary length (2.7 mm for water in air) separates the two regimes. The Ohnesorge number, independent of velocity, sorts atomisation and inkjet behaviour (printable fluids have about 0.1 < Oh < 1).

Weber number ρV²L/σ32.400
Bond number ΔρgL²/σ2.6453e-04
Capillary number μV/σ1.3714
Ohnesorge number μ/√(ρσL)0.24094
Capillary length √(σ/Δρg)1.8445mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 mm water drop at 2 m/s. The inputs, in the units selected above:

InputValue
Liquid density998.00 kg/m³
Density difference with the surrounding fluid997.00 kg/m³
Liquid viscosity1.0000 mPa·s
Surface tension72.800 mN/m
Velocity2.0000 m/s
Length scale (drop or jet diameter)2.0000 mm

Applying the formula below gives:

ResultValue
Weber number ρV²L/σ109.67
Bond number ΔρgL²/σ0.53721
Capillary number μV/σ0.027473
Ohnesorge number μ/√(ρσL)0.002623
Capillary length √(σ/Δρg)2.7287 mm

Open this example in the calculator and change any input.

Formula

\(We = \frac{\rho V^2L}{\sigma}, \quad Bo = \frac{\Delta\rho gL^2}{\sigma}, \quad Ca = \frac{\mu V}{\sigma}, \quad Oh = \frac{\mu}{\sqrt{\rho\sigma L}}\)

Variables

Symbol Meaning SI unit
\(\rho\) Liquid density kg/m³
\(\Delta\rho\) Density difference with the surrounding fluid kg/m³
\(\mu\) Liquid viscosity Pa·s
\(\sigma\) Surface tension N/m
\(V\) Velocity m/s
\(L\) Length scale (drop or jet diameter) m
\(We\) Weber number ρV²L/σ -
\(Bo\) Bond number ΔρgL²/σ -
\(Ca\) Capillary number μV/σ -
\(Oh\) Ohnesorge number μ/√(ρσL) -
\(\ell_c\) Capillary length √(σ/Δρg) m

Method and standards

Capillary numbers.

Where it is used

  • Sprays, atomisers, inkjets and bubble columns.
  • Microfluidics and coating flows.

Common mistakes

  • Using the wrong length scale.
  • Using liquid density instead of the density difference for Bond number.

Assumptions and limits

  • Clean interfaces; constant properties; g = 9.80665 m/s².

References

  • Dimensionless groups of capillarity

Questions and answers

Which length should I use?

The drop, bubble, jet or channel diameter that controls the problem.

Why use the density difference in the Bond number?

Buoyancy depends on the difference between the two fluids' densities.

What do the defaults represent?

An illustrative 2 mm water drop at 20 °C moving at 2 m/s through air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

White, Fluid Mechanics, 7th ed. (McGraw-Hill, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.