Worked example
Example: Illustrative 5 kg/s at 10 % quality. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total mass flow | 18,000 kg/h |
| Pipe inside diameter | 100.00 mm |
| Vapour (gas) mass quality | 10.000 % |
| Liquid density | 900.00 kg/m³ |
| Gas density | 5.0000 kg/m³ |
| Liquid viscosity | 0.15000 mPa·s |
| Gas viscosity | 0.015000 mPa·s |
| Pipe roughness | 0.045000 mm |
| Pipe length | 50.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Homogeneous mixture density | 47.619 kg/m³ |
| Mixture viscosity (McAdams) | 0.078947 mPa·s |
| Mixture velocity | 13.369 m/s |
| Reynolds number | 806,385 |
| Darcy friction factor | 0.016980 |
| Frictional pressure drop | 36.129 kPa |
Open this example in the calculator and change any input.
Formula
\(\rho_m = \left(\frac{x}{\rho_g} + \frac{1 - x}{\rho_l}\right)^{-1}, \quad \Delta p_f = f\frac{L}{D}\frac{G^2}{2\rho_m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Total mass flow | kg/s |
| \(D\) | Pipe inside diameter | m |
| \(x\) | Vapour (gas) mass quality | - |
| \(\rho_l\) | Liquid density | kg/m³ |
| \(\rho_g\) | Gas density | kg/m³ |
| \(\mu_l\) | Liquid viscosity | Pa·s |
| \(\mu_g\) | Gas viscosity | Pa·s |
| \(\varepsilon\) | Pipe roughness | m |
| \(L\) | Pipe length | m |
| \(\rho_m\) | Homogeneous mixture density | kg/m³ |
| \(\mu_m\) | Mixture viscosity (McAdams) | Pa·s |
| \(v_m\) | Mixture velocity | m/s |
| \(Re\) | Reynolds number | - |
| \(f\) | Darcy friction factor | - |
| \(\Delta p_f\) | Frictional pressure drop | Pa |
Method and standards
Homogeneous model.
Where it is used
- Flashing condensate and refrigerant lines.
- Two-phase relief and process lines.
Common mistakes
- Using it for stratified flow.
- Forgetting acceleration pressure drop in flashing lines.
Assumptions and limits
- Equal phase velocities; adiabatic; constant quality.
References
- Homogeneous equilibrium model
Questions and answers
When is the homogeneous model reasonable?
At high mass flux, in flashing flows and in bubbly or dispersed flows where the phases slip little.
Why does a little gas raise pressure drop so much?
Gas lowers the mixture density, so the velocity rises sharply for the same mass flow.
What do the defaults represent?
An illustrative 5 kg/s of a light hydrocarbon at 10 % vapour quality in a 100 mm pipe over 50 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Collier and Thome, Convective Boiling and Condensation, 3rd ed. (Oxford, 1994), ch. 2