Worked example
Example: 20 t/h solids to 600 g/L. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solids feed rate | 20.000 t/h |
| Underflow concentration | 600.00 g/L |
| Test 1 concentration | 100.00 g/L |
| Test 1 settling velocity | 1.2000e-04 m/s |
| Test 2 concentration | 200.00 g/L |
| Test 2 settling velocity | 4.0000e-05 m/s |
| Test 3 concentration | 300.00 g/L |
| Test 3 settling velocity | 1.5000e-05 m/s |
| Safety factor on area | 1.3000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Largest unit area, m² per kg/s of solids | 111.11 |
| Limiting concentration | 300.00 g/L |
| Thickener area (with safety factor) | 802.47 m² |
| Diameter | 31.965 m |
Open this example in the calculator and change any input.
Formula
\(A_u = \frac{1/C - 1/C_u}{u}, \quad A = f_s\,F_s\max_i A_{u,i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_s\) | Solids feed rate | kg/s |
| \(C_u\) | Underflow concentration | kg/m³ |
| \(C_1\) | Test 1 concentration | kg/m³ |
| \(u_1\) | Test 1 settling velocity | m/s |
| \(C_2\) | Test 2 concentration | kg/m³ |
| \(u_2\) | Test 2 settling velocity | m/s |
| \(C_3\) | Test 3 concentration | kg/m³ |
| \(u_3\) | Test 3 settling velocity | m/s |
| \(f_s\) | Safety factor on area | - |
| \(A_u\) | Largest unit area, m² per kg/s of solids | - |
| \(C_{lim}\) | Limiting concentration | kg/m³ |
| \(A\) | Thickener area (with safety factor) | m² |
| \(D\) | Diameter | m |
Method and standards
Coe–Clevenger flux method.
Where it is used
- Thickener sizing for mineral, lime and mud slurries.
Common mistakes
- Using a test concentration above the underflow.
- Ignoring flocculant effect.
Assumptions and limits
- Settling velocities from batch tests at the same flocculant dose.
- The unit area is a plain number in m² per kg/s of solids; divide by 86.4 for m² per t/d (the note gives both).
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 18 (thickening): Coe–Clevenger unit-area method from batch settling tests
Questions and answers
Why several tests?
Each concentration layer in the thickener must pass its solids flux; the worst layer sets the area.
What is unit area?
Area per unit of solids throughput, often m² per t/d.
Why a safety factor?
Batch tests overstate continuous performance; 1.2–1.5 is common.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.