Thickener Area by Coe–Clevenger (Batch Settling Tests)

Unit area and thickener area for a solids feed from settling velocities measured at several concentrations, taking the largest area (Coe–Clevenger).

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 20 t/h solids to 600 g/LLime mud

Results

Unit area A_u is in m² per (kg/s) of solids, here 98.77; that is 1.143 m² per t/d (divide by 86.4). The test that gives the largest unit area limits the design.

Largest unit area, m² per kg/s of solids98.765
Limiting concentration250.00g/L
Thickener area (with safety factor)263.37m²
Diameter18.312m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 t/h solids to 600 g/L. The inputs, in the units selected above:

InputValue
Solids feed rate20.000 t/h
Underflow concentration600.00 g/L
Test 1 concentration100.00 g/L
Test 1 settling velocity1.2000e-04 m/s
Test 2 concentration200.00 g/L
Test 2 settling velocity4.0000e-05 m/s
Test 3 concentration300.00 g/L
Test 3 settling velocity1.5000e-05 m/s
Safety factor on area1.3000 -

Applying the formula below gives:

ResultValue
Largest unit area, m² per kg/s of solids111.11
Limiting concentration300.00 g/L
Thickener area (with safety factor)802.47 m²
Diameter31.965 m

Open this example in the calculator and change any input.

Formula

\(A_u = \frac{1/C - 1/C_u}{u}, \quad A = f_s\,F_s\max_i A_{u,i}\)

Variables

Symbol Meaning SI unit
\(F_s\) Solids feed rate kg/s
\(C_u\) Underflow concentration kg/m³
\(C_1\) Test 1 concentration kg/m³
\(u_1\) Test 1 settling velocity m/s
\(C_2\) Test 2 concentration kg/m³
\(u_2\) Test 2 settling velocity m/s
\(C_3\) Test 3 concentration kg/m³
\(u_3\) Test 3 settling velocity m/s
\(f_s\) Safety factor on area -
\(A_u\) Largest unit area, m² per kg/s of solids -
\(C_{lim}\) Limiting concentration kg/m³
\(A\) Thickener area (with safety factor) m²
\(D\) Diameter m

Method and standards

Coe–Clevenger flux method.

Where it is used

  • Thickener sizing for mineral, lime and mud slurries.

Common mistakes

  • Using a test concentration above the underflow.
  • Ignoring flocculant effect.

Assumptions and limits

  • Settling velocities from batch tests at the same flocculant dose.
  • The unit area is a plain number in m² per kg/s of solids; divide by 86.4 for m² per t/d (the note gives both).

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 18 (thickening): Coe–Clevenger unit-area method from batch settling tests

Questions and answers

Why several tests?

Each concentration layer in the thickener must pass its solids flux; the worst layer sets the area.

What is unit area?

Area per unit of solids throughput, often m² per t/d.

Why a safety factor?

Batch tests overstate continuous performance; 1.2–1.5 is common.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.