Worked example
Example: Tray clarifier, 1 cm/min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| Juice volume per tonne cane | 0.90000 m³/t |
| Settling velocity | 10.000 mm/min |
| Installed settling area | 150.00 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Settling area needed | 150.00 m² |
| Area per t cane/h (m² per t/h) | 1.5000 m² |
| Crush the installed area serves | 100.00 t/h |
Open this example in the calculator and change any input.
Formula
\(S_r = \frac{A\,v_j}{u}, \quad A_S = \frac{S\,u}{v_j}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(v_j\) | Juice volume per tonne cane | m³/kg |
| \(u\) | Settling velocity | m/s |
| \(S\) | Installed settling area | m² |
| \(S_r\) | Settling area needed | m² |
| \(S_r/A\) | Area per t cane/h (shown as m² per t/h) | m² per t/h |
| \(A_S\) | Crush the installed area serves | kg/s |
Method and standards
Hindered-settling continuity.
Where it is used
- Clarifier selection.
- Checking capacity after a crush increase.
Common mistakes
- Using the tray area where the deflector blocks part of it.
- Mixing cm/min and m/h.
Assumptions and limits
- Settling velocity from jar tests or plant data.
- The juice volume is what reaches the clarifier: include returned filtrate, which adds 12–20 % (see the clarifier mud filtrate calculator).
- For a multi-tray clarifier the settling area is the sum of the trays.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 29
- capacity of clarifiers
- pp. 434–445
Questions and answers
Why area and not volume?
Mud settles at a fixed speed; the clear juice must rise more slowly than that, which depends on the area the flow spreads over.
Typical values?
Conventional tray clarifiers 1–2.5 m² per t cane/h; rapid clarifiers with flocculant 0.2–0.33.
What changes the settling velocity?
Flocculant, pH, temperature, phosphate and the amount of soil in the cane.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.