FireCADCalc

Juice Heater Velocity and Pressure Drop (Hugot)

Juice velocity, head loss and pressure drop through a multi-pass juice heater from flow, tubes per pass, passes, tube length and friction (Hugot 30.20–30.22).

Sugar mill and cogenerationPump

Inputs

Examples: Hugot example: 100 m3/h, 12 x 19 tubesClean heater

Hugot: smooth 0.016–0.020; scaled 0.025–0.100; 0.05 at the end of a week.

Results

The 3D added to each tube length covers the losses in the heads; Hugot's coefficient 0.0025 is λ/(2g) for λ = 0.05.

Juice velocity1.9370m/s
Head loss14.044m
Pressure drop144.61kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 100 m3/h, 12 x 19 tubes. The inputs, in the units selected above:

InputValue
Juice flow100.00 m³/h
Tube inside diameter31.000 mm
Tubes per pass19.000 -
Number of passes12.000 -
Tube length3.7000 m
Friction factor0.050000 -
Juice density1,050.0 kg/m³

Applying the formula below gives:

ResultValue
Juice velocity1.9370 m/s
Head loss14.044 m
Pressure drop144.61 kPa

Open this example in the calculator and change any input.

Formula

\(U = \frac{\dot V}{z\,\pi D^2/4}, \quad J = \frac{\lambda U^2}{2g}\,n\left(\frac{l}{D} + 3\right), \quad \Delta p = \rho_J g J\)

Variables

Symbol Meaning SI unit
\(\dot V\) Juice flow m³/s
\(D\) Tube inside diameter m
\(z\) Tubes per pass -
\(n\) Number of passes -
\(l\) Tube length m
\(\lambda\) Friction factor -
\(\rho_J\) Juice density kg/m³
\(U\) Juice velocity m/s
\(J\) Head loss m
\(\Delta p\) Pressure drop Pa
\(g\) Standard gravity, 9.806 65 m/s²

Method and standards

Darcy loss per pass with Hugot's allowance for the heads.

Where it is used

  • Juice pump sizing.
  • Choosing passes for a heater.

Common mistakes

  • Using outside diameter.
  • Forgetting the head allowance.

Assumptions and limits

  • Turbulent flow; λ from experience.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 30
  • eqns 30.20–30.22 and example
  • pp. 458–462

Questions and answers

Why does the friction factor rise so much?

Scale roughens the tubes: Hugot's λ goes from 0.02 clean to 0.05–0.1 after a week.

What velocity?

1.5–2 m/s: faster gives better heat transfer but more head; slower lets scale build.

Pump head?

Add the heads of all heaters in series, static lift and the clarifier inlet.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.