Worked example
Example: Raw juice 35 to 103 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice flow | 260.00 t/h |
| Juice specific heat | 3.9000 kJ/(kg·K) |
| Juice in | 35.000 °C |
| Juice out | 103.00 °C |
| Heating steam or vapour pressure (absolute) | 2.0000 bar |
| Heat losses (share of duty) | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heater duty | 19,153 kW |
| Steam saturation temperature | 120.21 °C |
| Latent heat at steam pressure | 2,201.6 kJ/kg |
| Steam condensed | 31.946 t/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_j c_p (T_2 - T_1), \quad T_s = T_{sat}(p_s), \quad h_{fg} = h_g(p_s) - h_f(p_s), \quad \dot m_s = \frac{\dot Q (1 + k_l)}{h_{fg}(p_s)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_j\) | Juice flow | kg/s |
| \(c_p\) | Juice specific heat | J/(kg·K) |
| \(T_1\) | Juice in | K |
| \(T_2\) | Juice out | K |
| \(p_s\) | Heating steam or vapour pressure (absolute) | Pa |
| \(k_l\) | Heat losses (share of duty) | - |
| \(\dot Q\) | Heater duty | W |
| \(T_s\) | Steam saturation temperature | K |
| \(h_{fg}\) | Latent heat at steam pressure | J/kg |
| \(\dot m_s\) | Steam condensed | kg/s |
Method and standards
Energy balance.
Where it is used
- Raw and clear juice heaters.
- Steam balance of the process house.
Common mistakes
- Gauge pressure for saturation.
- Ignoring heat losses.
Assumptions and limits
- Saturated condensate; saturated steam (no superheat credit, no condensate subcooling).
- The steam pressure is absolute: a gauge reading entered as absolute gives a saturation temperature about 20 K too low at 1 bar(g).
- c_p is your figure; the juice specific heat calculator gives it from brix and purity.
References
- Energy balance with IAPWS-IF97 latent heat; Hugot
- Handbook of Cane Sugar Engineering (juice heating)
Questions and answers
Why heat juice with vapour?
Vapour bled from an evaporator effect is cheaper than exhaust (Rillieux's principle).
What specific heat?
Mixed juice is close to water less a little for the dissolved solids, about 3.9 kJ/kg K.
Condensate sub-cooled?
Then each kg of steam gives slightly more heat; this calculator takes saturated condensate.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.