Worked example
Example: 250 TCH, 3.5 % cake. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Filter cake % cane | 3.5000 % |
| Filtration rate (cake per filter area) | 60.000 kg/(m²·h) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Filter cake made | 8.7500 t/h |
| Filter area | 145.83 m² |
Open this example in the calculator and change any input.
Formula
\(\dot m_{FC} = C\,FC, \quad A = \frac{\dot m_{FC}}{r}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Crushing rate | kg/s |
| \(FC\) | Filter cake % cane | - |
| \(r\) | Filtration rate (cake per filter area) | kg/(m²·s) |
| \(\dot m_{FC}\) | Filter cake made | kg/s |
| \(A\) | Filter area | m² |
Method and standards
Mass balance.
Where it is used
- Filter station sizing.
- Press mud for composting.
Common mistakes
- Mixing wet and dry cake rates.
Assumptions and limits
- Wet cake basis.
- The area per t cane/h is compared with the 0.3–0.8 m² of practice quoted by Hugot.
References
- Mass balance; cake % cane and filtration rate from Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 31
- Oliver filters
- pp. 473–483
Questions and answers
What is press mud used for?
Compost, often with distillery spent wash.
Why size on cake?
The filter's rating is the cake it discharges per square metre.
Pol loss?
Cake pol % cane is a determined loss in the pol balance.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.