Worked example
Example: 40 m2 ordinary. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Filter area | 40.000 m² |
| Air drawn per m² of filter | 12.800 m/h |
| Filtrate pump capacity per m² | 0.49000 m/h |
| Power per m² of filter | 0.80000 kW/m² |
| Cake output | 70.000 kg/(m²·h) |
| Time per drum revolution | 5.0000 min |
| Cake density | 1,300.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vacuum pump air | 512.00 m³/h |
| Filtrate pump | 19.600 m³/h |
| Power | 32.000 kW |
| Cake thickness | 4.4872 mm |
Open this example in the calculator and change any input.
Formula
\(\dot V_a = q_a S, \quad \dot V_f = q_f S, \quad P = e S, \quad e_c = \frac{g\,t_r}{\rho_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Filter area | m² |
| \(q_a\) | Air drawn per m² of filter | m/s |
| \(q_f\) | Filtrate pump capacity per m² | m/s |
| \(e\) | Power per m² of filter | W/m² |
| \(g\) | Cake output | kg/(m²·s) |
| \(t_r\) | Time per drum revolution | s |
| \(\rho_c\) | Cake density | kg/m³ |
| \(\dot V_a\) | Vacuum pump air | m³/s |
| \(\dot V_f\) | Filtrate pump | m³/s |
| \(P\) | Power | W |
| \(e_c\) | Cake thickness | m |
Method and standards
Hugot's specific capacities.
Where it is used
- Sizing filter auxiliaries.
- Checking cake formation.
Common mistakes
- Using air at vacuum as free air.
- Mixing wet and dry cake rates.
Assumptions and limits
- Specific figures from practice.
- The air volume is on the same basis as the specific figure entered; free air at atmosphere and air at the filter vacuum differ by the pressure ratio (about 2 at 50 cmHg), so state the basis when sizing the pump.
- The cake thickness is compared with Hugot's 7–13 mm.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 31
- Oliver filters
- pp. 473–483
Questions and answers
Why so much air?
Air leaks through the cake once it forms; flocculated cakes are more open and need more.
How thick should the cake be?
About 7 mm: thicker cakes wash poorly.
Two vacuums?
Low vacuum (25–40 cmHg) to form cake, high (40–50) to wash and dry it.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.