Worked example
Example: 6 hours. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Time the mud is held | 6.0000 h |
| Purity of the mud juice when settled | 84.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Purity drop (points) | 0.60000 % |
| Purity after holding | 83.400 % |
Open this example in the calculator and change any input.
Formula
\(\Delta P = \frac{t}{10}\ (0 < t \le 10\ \mathrm h), \quad \Delta P = \frac{t^2}{100}\ (t \ge 10\ \mathrm h)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(t\) | Time the mud is held | s |
| \(P_0\) | Purity of the mud juice when settled | - |
| \(\Delta P\) | Purity drop (points) | - |
| \(P\) | Purity after holding | - |
Method and standards
Hugot's empirical rule.
Where it is used
- Weekend shutdown planning.
- Judging mud handling.
Common mistakes
- Applying it to clear juice.
- Using days instead of hours.
Assumptions and limits
- Mud near 95 °C, pH 6–6.5; temperature and pH are not inputs. Apparent purity (brix and pol), as in routine control.
- Beyond about a day the rule is an extrapolation; a note appears.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 29
- eqn 29.1
- p. 433
Questions and answers
Why does mud lose purity?
Sucrose inverts and decomposes in hot, slightly acid mud, and microbes act if it cools.
Why the change of formula at 10 hours?
The loss accelerates as the mud turns sour; Hugot's rule switches from linear to quadratic.
How to limit it?
Short-retention clarifiers and filtering mud promptly.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.