Worked example
Example: 3 ppm, 0.1 % solution. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice flow | 250.00 m³/h |
| Flocculant dose (mg per litre of juice) | 3.0000 mg/L |
| Solution strength | 0.10000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flocculant per hour | 0.75000 kg/h |
| Flocculant per day | 18.000 kg/d |
| Solution flow (density 1000 kg/m³) | 750.00 L/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_f = \dot V_j c, \quad \dot V_s = \frac{\dot m_f}{w\,\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_j\) | Juice flow | m³/s |
| \(c\) | Flocculant dose | kg/m³ |
| \(w\) | Solution strength | - |
| \(\dot m_f\) | Flocculant per hour | kg/s |
| \(\dot m_{f,d}\) | Flocculant per day | kg/s |
| \(\dot V_s\) | Solution flow (density 1000 kg/m³) | m³/s |
Method and standards
Mass balance.
Where it is used
- Clarifier chemical dosing.
- Chemical budgets.
Common mistakes
- Dose in ppm by mass of juice mixed with mg/L.
Assumptions and limits
- Solution density as water.
- The dose is per litre of juice. Doses quoted in ppm on cane must be converted with the juice-to-cane ratio before entry. No dose range is given here: find the optimum by jar tests.
References
- Mass balance ṁ = V̇ c; solution flow = ṁ/(w ρ)
Questions and answers
Typical dose?
A few ppm on juice; find the optimum by jar tests.
Why dilute?
Strong solutions do not disperse before flocs form.
Overdosing?
Wastes chemical and can give fluffy, slow mud.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.