Worked example
Example: Raise 150 to 300 ppm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice flow | 250.00 m³/h |
| Target P₂O₅ in juice | 300.00 mg/L |
| P₂O₅ already in juice | 150.00 mg/L |
| Acid strength (H₃PO₄ mass fraction) | 85.000 % |
| Acid density | 1,685.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| P₂O₅ added | 37.500 kg/h |
| Pure H₃PO₄ | 51.778 kg/h |
| Commercial acid | 60.916 kg/h |
| Commercial acid volume | 36.152 L/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_{H_3PO_4} = \dot m_{P_2O_5}\frac{2 M_{H_3PO_4}}{M_{P_2O_5}}, \quad \dot m_a = \frac{\dot m_{H_3PO_4}}{w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_j\) | Juice flow | m³/s |
| \(c_t\) | Target P₂O₅ in juice | kg/m³ |
| \(c_0\) | P₂O₅ already in juice | kg/m³ |
| \(w\) | Acid strength (H₃PO₄ mass fraction) | - |
| \(\rho_a\) | Acid density | kg/m³ |
| \(\dot m_{P_2O_5}\) | P₂O₅ added | kg/s |
| \(\dot m_{H_3PO_4}\) | Pure H₃PO₄ | kg/s |
| \(\dot m_a\) | Commercial acid | kg/s |
| \(\dot V_a\) | Commercial acid volume | m³/s |
Method and standards
Stoichiometry.
Where it is used
- Clarification chemical dosing.
- Chemical cost reports.
Common mistakes
- ppm on mass treated as mg/L without density.
Assumptions and limits
- Uniform juice flow.
- P₂O₅ concentrations are mg per litre of juice; ppm by mass is lower by the juice density (about 1.06).
- The acid density is entered separately and must match the acid strength.
References
- Stoichiometry P₂O₅ + 3 H₂O → 2 H₃PO₄ with IUPAC atomic masses
Questions and answers
Why phosphate?
Calcium phosphate flocs carry colloids and colour down in the clarifier.
How much P₂O₅ in juice?
Cane varies; mills dose to a target, often around 250–350 ppm. The page works in mg/L of juice; check whether a target is per litre, per kg of juice (juice density about 1.06) or on brix before entering it.
Why convert to H₃PO₄?
The acid bought is H₃PO₄; 1 kg P₂O₅ is about 1.38 kg H₃PO₄.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.