Mixer–Settler: Mixer Volume and Settler Area

Mixer volume from residence time and settler area from the specific settler flow for a liquid–liquid extraction mixer–settler, with settler residence time.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 20 + 20 m³/h, 3 min, 4 m/hCopper SX 300 + 300 m³/h

Results

Specific settler flow comes from batch settling tests or pilot data; 3–6 m³/(m²·h) of total flow is common in metal extraction.

Mixer volume20.000m³
Settler area120.00m²
Settler volume120.00m³
Settler residence time12.000min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 + 20 m³/h, 3 min, 4 m/h. The inputs, in the units selected above:

InputValue
Aqueous flow20.000 m³/h
Organic flow20.000 m³/h
Mixer residence time3.0000 min
Specific settler flow4.0000 m/h
Settler liquid depth0.80000 m

Applying the formula below gives:

ResultValue
Mixer volume2.0000 m³
Settler area10.000 m²
Settler volume8.0000 m³
Settler residence time12.000 min

Open this example in the calculator and change any input.

Formula

\(V_m = (Q_a + Q_o)t_m, \quad A_s = \frac{Q_a + Q_o}{q_s}, \quad t_s = \frac{A_sH}{Q_a + Q_o}\)

Variables

Symbol Meaning SI unit
\(Q_a\) Aqueous flow m³/s
\(Q_o\) Organic flow m³/s
\(t_m\) Mixer residence time s
\(q_s\) Specific settler flow m/s
\(H\) Settler liquid depth m
\(V_m\) Mixer volume m³
\(A_s\) Settler area m²
\(V_s\) Settler volume m³
\(t_s\) Settler residence time s

Method and standards

Residence time and specific flow.

Where it is used

  • Solvent extraction plants.
  • Washing and phase separation stages.

Common mistakes

  • Using only one phase's flow.
  • Ignoring recycle to the mixer.

Assumptions and limits

  • Specific settler flow from tests.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 15 (mixer–settlers: specific settler flow)

Questions and answers

Why size the settler by area?

Drops coalesce at the dispersion band; its throughput per unit area, not volume, limits the settler.

How long is mixing?

1–3 minutes is usual for fast extractions; slow chemistry needs more.

What do the defaults represent?

A small metal-extraction stage with equal aqueous and organic flows.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.