Worked example
Example: 20 + 20 m³/h, 3 min, 4 m/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Aqueous flow | 20.000 m³/h |
| Organic flow | 20.000 m³/h |
| Mixer residence time | 3.0000 min |
| Specific settler flow | 4.0000 m/h |
| Settler liquid depth | 0.80000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mixer volume | 2.0000 m³ |
| Settler area | 10.000 m² |
| Settler volume | 8.0000 m³ |
| Settler residence time | 12.000 min |
Open this example in the calculator and change any input.
Formula
\(V_m = (Q_a + Q_o)t_m, \quad A_s = \frac{Q_a + Q_o}{q_s}, \quad t_s = \frac{A_sH}{Q_a + Q_o}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_a\) | Aqueous flow | m³/s |
| \(Q_o\) | Organic flow | m³/s |
| \(t_m\) | Mixer residence time | s |
| \(q_s\) | Specific settler flow | m/s |
| \(H\) | Settler liquid depth | m |
| \(V_m\) | Mixer volume | m³ |
| \(A_s\) | Settler area | m² |
| \(V_s\) | Settler volume | m³ |
| \(t_s\) | Settler residence time | s |
Method and standards
Residence time and specific flow.
Where it is used
- Solvent extraction plants.
- Washing and phase separation stages.
Common mistakes
- Using only one phase's flow.
- Ignoring recycle to the mixer.
Assumptions and limits
- Specific settler flow from tests.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 15 (mixer–settlers: specific settler flow)
Questions and answers
Why size the settler by area?
Drops coalesce at the dispersion band; its throughput per unit area, not volume, limits the settler.
How long is mixing?
1–3 minutes is usual for fast extractions; slow chemistry needs more.
What do the defaults represent?
A small metal-extraction stage with equal aqueous and organic flows.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.