Worked example
Example: Ideal log mean. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mole fraction of liquid 1 | 50.000 % |
| Viscosity of liquid 1 | 0.60000 cP |
| Viscosity of liquid 2 | 1.2000 cP |
| Interaction parameter (0 = ideal) | 0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mixture viscosity | 0.84853 cP |
| Viscosity with G₁₂ = 0 (log mean) | 0.84853 cP |
Open this example in the calculator and change any input.
Formula
\(\ln\mu_m = x_1\ln\mu_1 + x_2\ln\mu_2 + x_1x_2G_{12}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | Mole fraction of liquid 1 | - |
| \(\mu_1\) | Viscosity of liquid 1 | Pa·s |
| \(\mu_2\) | Viscosity of liquid 2 | Pa·s |
| \(G_{12}\) | Interaction parameter (0 = ideal) | - |
| \(\mu_m\) | Mixture viscosity | Pa·s |
| \(\mu_{ideal}\) | Viscosity with G₁₂ = 0 (log mean) | Pa·s |
Method and standards
Grunberg–Nissan equation.
Where it is used
- Solvent and process liquid properties.
Common mistakes
- Using mass fractions.
- Assuming G₁₂ = 0 for associating liquids.
Assumptions and limits
- Binary; same temperature for all viscosities.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2 (transport properties): Grunberg–Nissan equation
Questions and answers
What is G₁₂?
A binary interaction parameter fitted to data; zero gives the logarithmic (Arrhenius) mean.
Is it good for water mixtures?
Aqueous and alcohol mixtures need large G₁₂ and may peak above both pure viscosities.
Can it blend fuel oils?
Oil blending usually uses the Refutas or ASTM D341 methods instead.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.