Worked example
Example: 50 cP oil. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dynamic viscosity (choose its unit) | 50.000 cP |
| Density | 890.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| pascal second | 0.050000 Pa·s |
| centipoise (mPa·s) | 50.000 cP |
| poise | 0.50000 P |
| pound per foot second | 0.033598 lb/(ft·s) |
| kinematic, m²/s | 5.6180e-05 m²/s |
| kinematic, centistokes | 56.180 cSt |
| kinematic, stokes | 0.56180 St |
| kinematic, ft²/s | 6.0471e-04 ft²/s |
Open this example in the calculator and change any input.
Formula
\(\nu = \frac{\mu}{\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\mu\) | Dynamic viscosity (choose its unit) | Pa·s |
| \(\rho\) | Density | kg/m³ |
| \(\nu\) | kinematic, m²/s | m²/s |
Method and standards
Definition.
Where it is used
- Fuel oil and lube oil data sheets.
- Pump and pipe calculations.
Common mistakes
- cP vs cSt without density.
- Viscosity at the wrong temperature.
Assumptions and limits
The input is a dynamic viscosity. To start from a kinematic value (a furnace oil in cSt, say), use the dynamic and kinematic viscosity conversion calculator, which takes either.
Newtonian fluid.
References
- ν = μ/ρ; unit definitions per NIST SP 811
Questions and answers
50 cP oil at 890 kg/m³?
About 56.2 cSt.
Water at 20 °C?
About 1 cP and 1 cSt, because its density is near 1000 kg/m³.
Furnace oil specs in cSt?
Kinematic, at the stated temperature.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.