FireCADCalc

Adsorption Capacity: Langmuir and Freundlich Isotherms

Equilibrium loading of an adsorbent by the Langmuir and Freundlich isotherms, and the adsorbent mass to take up a solute load (Perry's sec. 16).

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 0.05 kg/m3, 10 kg soluteDilute 5 mg/LK_F 20 mg/g with c in mg/L, 5 mg/L

Results

The adsorbent mass is the equilibrium minimum; real beds need more because of the unused mass-transfer zone.

Langmuir loading0.12500kg/kg
Freundlich loading0.068399kg/kg
Adsorbent needed (Langmuir)16.000kg
Adsorbent needed (Freundlich)29.240kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.05 kg/m3, 10 kg solute. The inputs, in the units selected above:

InputValue
Fluid-phase concentration50.000 mg/L
Langmuir monolayer capacity0.30000 kg/kg
Langmuir constant50.000 m³/kg
Freundlich constant (q at c = 1 kg/m³)0.50000 kg/kg
Freundlich exponent n (q = K_F c^{1/n})2.5000 -
Solute to remove10.000 kg
Basis of K_FSI: q in kg/kg at c = 1 kg/m³

Applying the formula below gives:

ResultValue
Langmuir loading0.21429 kg/kg
Freundlich loading0.15085 kg/kg
Adsorbent needed (Langmuir)46.667 kg
Adsorbent needed (Freundlich)66.289 kg

Open this example in the calculator and change any input.

Formula

\(q_L = \frac{q_m K_L c}{1 + K_L c}, \quad q_F = K_F c^{1/n}, \quad M_{ads} = \frac{M_s}{q}\)

Variables

Symbol Meaning SI unit
\(c\) Fluid-phase concentration kg/m³
\(q_m\) Langmuir monolayer capacity kg/kg
\(K_L\) Langmuir constant m³/kg
\(K_F\) Freundlich constant (q at c = 1 kg/m³) kg/kg
\(n\) Freundlich exponent n (q = K_F c^{1/n}) -
\(M_s\) Solute to remove kg
\(q_L\) Langmuir loading kg/kg
\(q_F\) Freundlich loading kg/kg
\(M_{ads,L}\) Adsorbent needed (Langmuir) kg
\(M_{ads,F}\) Adsorbent needed (Freundlich) kg
\(\text{basis}\) Basis of K_F -

Method and standards

Isotherms as in Perry's sec. 16.

Where it is used

  • Carbon dose for water and spirit polishing.
  • Adsorber design.

Common mistakes

  • Using fitted constants outside the measured range.
  • Mixing mg/L and kg/m³ (they are equal: mg/L = g/m³).

Assumptions and limits

  • Equilibrium; single solute.
  • K_F depends on the concentration unit. Most published values use q in mg/g with c in mg/L; choose that basis so the calculator converts c, otherwise a K_F with n = 2.5 is out by a factor of about 16.
  • At zero concentration the adsorbent masses are not shown.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 16 (adsorption equilibrium): Langmuir and Freundlich isotherms

Questions and answers

Which isotherm fits?

Langmuir for monolayer adsorption with saturation; Freundlich for heterogeneous surfaces over a moderate range.

Why units of K_L in m³/kg?

K_L c must be dimensionless with c in kg/m³.

Can the adsorbent mass be infinite?

At zero concentration the loading is zero, so no finite mass reaches it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.