Worked example
Example: 0.05 kg/m3, 10 kg solute. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid-phase concentration | 50.000 mg/L |
| Langmuir monolayer capacity | 0.30000 kg/kg |
| Langmuir constant | 50.000 m³/kg |
| Freundlich constant (q at c = 1 kg/m³) | 0.50000 kg/kg |
| Freundlich exponent n (q = K_F c^{1/n}) | 2.5000 - |
| Solute to remove | 10.000 kg |
| Basis of K_F | SI: q in kg/kg at c = 1 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Langmuir loading | 0.21429 kg/kg |
| Freundlich loading | 0.15085 kg/kg |
| Adsorbent needed (Langmuir) | 46.667 kg |
| Adsorbent needed (Freundlich) | 66.289 kg |
Open this example in the calculator and change any input.
Formula
\(q_L = \frac{q_m K_L c}{1 + K_L c}, \quad q_F = K_F c^{1/n}, \quad M_{ads} = \frac{M_s}{q}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(c\) | Fluid-phase concentration | kg/m³ |
| \(q_m\) | Langmuir monolayer capacity | kg/kg |
| \(K_L\) | Langmuir constant | m³/kg |
| \(K_F\) | Freundlich constant (q at c = 1 kg/m³) | kg/kg |
| \(n\) | Freundlich exponent n (q = K_F c^{1/n}) | - |
| \(M_s\) | Solute to remove | kg |
| \(q_L\) | Langmuir loading | kg/kg |
| \(q_F\) | Freundlich loading | kg/kg |
| \(M_{ads,L}\) | Adsorbent needed (Langmuir) | kg |
| \(M_{ads,F}\) | Adsorbent needed (Freundlich) | kg |
| \(\text{basis}\) | Basis of K_F | - |
Method and standards
Isotherms as in Perry's sec. 16.
Where it is used
- Carbon dose for water and spirit polishing.
- Adsorber design.
Common mistakes
- Using fitted constants outside the measured range.
- Mixing mg/L and kg/m³ (they are equal: mg/L = g/m³).
Assumptions and limits
- Equilibrium; single solute.
- K_F depends on the concentration unit. Most published values use q in mg/g with c in mg/L; choose that basis so the calculator converts c, otherwise a K_F with n = 2.5 is out by a factor of about 16.
- At zero concentration the adsorbent masses are not shown.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 16 (adsorption equilibrium): Langmuir and Freundlich isotherms
Questions and answers
Which isotherm fits?
Langmuir for monolayer adsorption with saturation; Freundlich for heterogeneous surfaces over a moderate range.
Why units of K_L in m³/kg?
K_L c must be dimensionless with c in kg/m³.
Can the adsorbent mass be infinite?
At zero concentration the loading is zero, so no finite mass reaches it.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.