Worked example
Example: E = 2, 5 % to 0.2 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solute in the feed (solute-free ratio, kg per kg carrier) | 5.0000 % |
| Solute in the raffinate (solute-free ratio) | 0.20000 % |
| Solute in the entering solvent (solute-free ratio) | 0 % |
| Distribution ratio y/x | 2.5000 - |
| Solvent to feed ratio (solute-free basis) | 0.80000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Extraction factor K S/F | 2.0000 |
| Theoretical stages | 3.7004 |
| Solute extracted | 96.000 % |
Open this example in the calculator and change any input.
Formula
\(N = \frac{\ln\left[\frac{x_F - y_S/K}{x_R - y_S/K}\left(1 - \frac{1}{E}\right) + \frac{1}{E}\right]}{\ln E}, \quad E = \frac{KS}{F}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_F\) | Solute in the feed | - |
| \(x_R\) | Solute in the raffinate | - |
| \(y_S\) | Solute in the entering solvent | - |
| \(K\) | Distribution ratio y/x | - |
| \(S/F\) | Solvent to feed ratio (solute-free basis) | - |
| \(E\) | Extraction factor K S/F | - |
| \(N\) | Theoretical stages | - |
| \(\eta\) | Solute extracted | - |
Method and standards
Kremser equation for extraction.
Where it is used
- Solvent extraction design.
- Checking mixer-settler trains.
Common mistakes
- Using mass ratios with molar K.
- Ignoring solvent solute.
Assumptions and limits
- Dilute; immiscible solvents; constant K.
- Concentrations are solute-free ratios X = x/(1 − x) (kg solute per kg carrier or solvent), consistent with S/F on a solute-free basis. Entering mass fractions instead is close only when dilute: at 5 % the difference is about 5 %.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 15 (liquid–liquid extraction): Kremser equation with the extraction factor
Questions and answers
What extraction factor is sensible?
1.3–2: below 1 the recovery is limited however many stages are used.
Why solute-free basis?
Kremser assumes constant solvent and feed flows, true for dilute solutions.
Is K constant?
Only for dilute systems; check against the equilibrium curve.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.