Worked example
Example: Air, α 5, cut 0.3, pressure ratio 0.1. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fast gas mole fraction in the feed | 20.900 % |
| Stage cut (permeate/feed) | 30.000 % |
| Selectivity (fast/slow permeability) | 5.0000 - |
| Pressure ratio (permeate/feed side) | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fast gas in the permeate | 37.938 % |
| Fast gas in the retentate | 13.598 % |
| Recovery of the fast gas to the permeate | 54.456 % |
Open this example in the calculator and change any input.
Formula
\(\frac{y_p}{1 - y_p} = \alpha\frac{x_o - (p_L/p_H)y_p}{(1 - x_o) - (p_L/p_H)(1 - y_p)}, \quad x_f = \theta y_p + (1 - \theta)x_o\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_f\) | Fast gas mole fraction in the feed | - |
| \(\theta\) | Stage cut (permeate/feed) | - |
| \(\alpha\) | Selectivity (fast/slow permeability) | - |
| \(p_L/p_H\) | Pressure ratio (permeate/feed side) | - |
| \(y_p\) | Fast gas in the permeate | - |
| \(x_o\) | Fast gas in the retentate | - |
| \(R\) | Recovery of the fast gas to the permeate | - |
Method and standards
Complete-mixing model.
Where it is used
- Nitrogen generators and oxygen enrichment.
- Hydrogen recovery and CO₂ removal screening.
Common mistakes
- Using ideal selectivity for mixed-gas operation.
- Ignoring permeate back-pressure.
Assumptions and limits
- Binary; complete mixing; constant permeabilities.
- The two nested solutions are checked against both equations; if they do not close, the calculation stops with a message instead of returning a bracket end point.
References
- Weller and Steiner (1950) complete-mixing model
- as given in Geankoplis
- Transport Processes and Separation Process Principles
- and Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 20
Questions and answers
Why does pressure ratio matter?
Permeation is driven by partial pressure difference; if permeate pressure is not low, even a very selective membrane cannot enrich much.
What is stage cut?
The share of feed that permeates; higher cut recovers more fast gas but at lower purity.
What do the defaults represent?
Air (20.9 % O₂) on a membrane with O₂/N₂ selectivity 5, 30 % stage cut and permeate at a tenth of feed pressure.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.