FireCADCalc

Constant-Rate Drying Time

Drying time in the constant-rate period from dry solids, drying area, initial and critical moisture and the rate h(T − T_w)/λ_w (Perry's sec. 12).

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 500 kg on 25 m2 trays, 80 °C airBelt dryer 120 °C

Results

Constant drying rate1.8000kg/(m²·h)
Constant-rate drying time5.5556h
Water removed250.00kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 500 kg on 25 m2 trays, 80 °C air. The inputs, in the units selected above:

InputValue
Dry solids500.00 kg
Drying surface25.000 m²
Initial moisture (dry basis)0.80000 kg/kg
Critical moisture (dry basis)0.30000 kg/kg
Gas-to-surface heat transfer coefficient30.000 W/(m²·K)
Gas temperature80.000 °C
Wet-bulb (surface) temperature40.000 °C
Latent heat at the wet-bulb temperature2,400.0 kJ/kg

Applying the formula below gives:

ResultValue
Constant drying rate1.8000 kg/(m²·h)
Constant-rate drying time5.5556 h
Water removed250.00 kg

Open this example in the calculator and change any input.

Formula

\(N_c = \frac{h(T_g - T_w)}{\lambda_w}, \quad t_c = \frac{m_s(X_1 - X_c)}{A N_c}\)

Variables

Symbol Meaning SI unit
\(m_s\) Dry solids kg
\(A\) Drying surface m²
\(X_1\) Initial moisture (dry basis) kg/kg
\(X_c\) Critical moisture (dry basis) kg/kg
\(h\) Gas-to-surface heat transfer coefficient W/(m²·K)
\(T_g\) Gas temperature K
\(T_w\) Wet-bulb (surface) temperature K
\(\lambda_w\) Latent heat at the wet-bulb temperature J/kg
\(N_c\) Constant drying rate kg/(m²·s)
\(t_c\) Constant-rate drying time s
\(W\) Water removed kg

Method and standards

Heat-transfer-limited constant drying rate.

Where it is used

  • Tray, belt and tunnel dryer sizing.
  • Drying trials scale-up.

Common mistakes

  • Using wet basis moisture.
  • Taking the dry-bulb temperature as the surface temperature.

Assumptions and limits

  • Radiation and conduction to the surface neglected.
  • The latent heat is an input so other liquids can be used; for water a note appears when it differs by more than 2 % from the IAPWS-IF97 value at the wet-bulb temperature.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 12 (drying): constant-rate period controlled by heat transfer to the surface at the wet-bulb temperature

Questions and answers

Why is the surface at the wet-bulb temperature?

While the surface stays wet, heat arriving equals latent heat leaving, as on a wet-bulb thermometer.

What sets the rate?

Gas temperature, velocity (through h) and humidity (through T_w).

What happens below X_c?

The surface dries out and the rate falls; use the falling-rate calculator.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.