Worked example
Example: 500 kg on 25 m2 trays, 80 °C air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids | 500.00 kg |
| Drying surface | 25.000 m² |
| Initial moisture (dry basis) | 0.80000 kg/kg |
| Critical moisture (dry basis) | 0.30000 kg/kg |
| Gas-to-surface heat transfer coefficient | 30.000 W/(m²·K) |
| Gas temperature | 80.000 °C |
| Wet-bulb (surface) temperature | 40.000 °C |
| Latent heat at the wet-bulb temperature | 2,400.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Constant drying rate | 1.8000 kg/(m²·h) |
| Constant-rate drying time | 5.5556 h |
| Water removed | 250.00 kg |
Open this example in the calculator and change any input.
Formula
\(N_c = \frac{h(T_g - T_w)}{\lambda_w}, \quad t_c = \frac{m_s(X_1 - X_c)}{A N_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_s\) | Dry solids | kg |
| \(A\) | Drying surface | m² |
| \(X_1\) | Initial moisture (dry basis) | kg/kg |
| \(X_c\) | Critical moisture (dry basis) | kg/kg |
| \(h\) | Gas-to-surface heat transfer coefficient | W/(m²·K) |
| \(T_g\) | Gas temperature | K |
| \(T_w\) | Wet-bulb (surface) temperature | K |
| \(\lambda_w\) | Latent heat at the wet-bulb temperature | J/kg |
| \(N_c\) | Constant drying rate | kg/(m²·s) |
| \(t_c\) | Constant-rate drying time | s |
| \(W\) | Water removed | kg |
Method and standards
Heat-transfer-limited constant drying rate.
Where it is used
- Tray, belt and tunnel dryer sizing.
- Drying trials scale-up.
Common mistakes
- Using wet basis moisture.
- Taking the dry-bulb temperature as the surface temperature.
Assumptions and limits
- Radiation and conduction to the surface neglected.
- The latent heat is an input so other liquids can be used; for water a note appears when it differs by more than 2 % from the IAPWS-IF97 value at the wet-bulb temperature.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (drying): constant-rate period controlled by heat transfer to the surface at the wet-bulb temperature
Questions and answers
Why is the surface at the wet-bulb temperature?
While the surface stays wet, heat arriving equals latent heat leaving, as on a wet-bulb thermometer.
What sets the rate?
Gas temperature, velocity (through h) and humidity (through T_w).
What happens below X_c?
The surface dries out and the rate falls; use the falling-rate calculator.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.