FireCADCalc

Compressor Polytropic Head, Power and Discharge Temperature

Polytropic head, gas power and discharge temperature of a compressor from suction state, pressure ratio, molar mass, k, Z and polytropic efficiency.

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textileAir compressor and receiver

Inputs

Examples: Air 5 kg/s, 1 → 4 barNatural gas 20 → 60 bar

Results

Keep discharge temperature within the lube and seal limits; intercool when the ratio per stage exceeds about 3–4.

Polytropic exponent term0.26575
Polytropic head171.87kJ/kg
Discharge temperature132.78°C
Gas power2,148.4kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air 5 kg/s, 1 → 4 bar. The inputs, in the units selected above:

InputValue
Gas mass flow18,000 kg/h
Suction temperature35.000 °C
Suction pressure (absolute)1.0000 bar
Discharge pressure (absolute)4.0000 bar
Molar mass28.960 kg/kmol
Ratio of specific heats1.4000 -
Mean compressibility1.0000 -
Polytropic efficiency78.000 %

Applying the formula below gives:

ResultValue
Polytropic exponent term0.36630
Polytropic head159.80 kJ/kg
Discharge temperature238.88 °C
Gas power1,024.4 kW

Open this example in the calculator and change any input.

Formula

\(\frac{n - 1}{n} = \frac{k - 1}{k\eta_p}, \quad H_p = \frac{ZRT_1}{M}\frac{n}{n - 1}\left[\left(\frac{p_2}{p_1}\right)^{(n-1)/n} - 1\right], \quad T_2 = T_1\left(\frac{p_2}{p_1}\right)^{(n-1)/n}, \quad P = \frac{\dot m H_p}{\eta_p}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Gas mass flow kg/s
\(T_1\) Suction temperature K
\(p_1\) Suction pressure (absolute) Pa
\(p_2\) Discharge pressure (absolute) Pa
\(M\) Molar mass kg/kmol
\(k\) Ratio of specific heats -
\(Z\) Mean compressibility -
\(\eta_p\) Polytropic efficiency -
\((n - 1)/n\) Polytropic exponent term -
\(H_p\) Polytropic head J/kg
\(T_2\) Discharge temperature K
\(P\) Gas power W

Method and standards

Polytropic compression of an ideal gas with a mean Z.

Where it is used

  • Process gas and air compressor checks.

Common mistakes

  • Mixing isentropic and polytropic efficiencies.
  • Using gauge pressures.

Assumptions and limits

  • Constant k and Z; no intercooling. Above a ratio of about 4 the result is for uncooled compression and a note suggests intercooled stages.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 10 (compressors): polytropic compression

Questions and answers

Why polytropic rather than isentropic?

Polytropic efficiency is independent of pressure ratio, so it is used for multistage centrifugal machines.

How is n linked to efficiency?

(n − 1)/n = (k − 1)/(k η_p).

Is Z needed?

For real gases at pressure; use the mean of suction and discharge values.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.