FireCADCalc

Size Reduction Energy: Kick, Rittinger and Bond

Size reduction energy by Kick's, Rittinger's and Bond's laws, with Kick and Rittinger constants calibrated from one test (Perry's Eqs. 21-121 to 21-123).

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Test 10 kWh/t for 50→5 mm; duty 25→1 mmFine grinding

Results

Kick's law energy22.499kWh/t
Rittinger's law energy54.815kWh/t
Bond's law energy10.062kWh/t
Power by Bond's law100.62kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Test 10 kWh/t for 50→5 mm; duty 25→1 mm. The inputs, in the units selected above:

InputValue
Test: specific energy10.000 kWh/t
Test: feed size (80 % passing)50.000 mm
Test: product size (80 % passing)5.0000 mm
Duty: feed size (80 % passing)25.000 mm
Duty: product size (80 % passing)1.0000 mm
Bond work index15.000 kWh/t
Throughput50.000 t/h

Applying the formula below gives:

ResultValue
Kick's law energy13.979 kWh/t
Rittinger's law energy53.333 kWh/t
Bond's law energy3.7947 kWh/t
Power by Bond's law189.74 kW

Open this example in the calculator and change any input.

Formula

\(E_K = C_K\ln\frac{X_F}{X_P}, \quad E_R = C_R\left(\frac{1}{X_P} - \frac{1}{X_F}\right), \quad E_B = 10E_i\left(\frac{1}{\sqrt{X_P}} - \frac{1}{\sqrt{X_F}}\right)\ (\mu m)\)

Variables

Symbol Meaning SI unit
\(E_0\) Test: specific energy J/kg
\(X_{F0}\) Test: feed size (80 % passing) m
\(X_{P0}\) Test: product size (80 % passing) m
\(X_F\) Duty: feed size (80 % passing) m
\(X_P\) Duty: product size (80 % passing) m
\(E_i\) Bond work index J/kg
\(\dot m\) Throughput kg/s
\(E_K\) Kick's law energy J/kg
\(E_R\) Rittinger's law energy J/kg
\(E_B\) Bond's law energy J/kg
\(P_B\) Power by Bond's law W

Method and standards

Walker's general law integrated for n = 1, 2 and 1.5.

Where it is used

  • Crusher and mill selection.
  • Comparing grinding duties.

Common mistakes

  • Mixing mean sizes with 80 % passing sizes.
  • Extrapolating far beyond the test duty.

Assumptions and limits

  • Same material and machine type as the test.
  • Sizes are 80 % passing sizes, as Bond's law requires; use the same basis for the test so the three laws compare.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 21
  • Eqs. (21-120) to (21-123): Kick
  • Rittinger and Bond

Questions and answers

Which law should I use?

Kick for coarse crushing, Rittinger for fine grinding, Bond (between them) for most mills.

Why calibrate on a test?

The constants depend on the material and machine; one test at a similar duty fixes them.

What sizes does Bond use?

The 80 % passing sizes in micrometres, with E_i in kWh per short or metric tonne.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.