FireCADCalc

Fixed-Bed Adsorber by the Bed-Depth Service-Time Model

Service time to breakthrough of a fixed-bed adsorber from bed depth, velocity, feed concentration and the BDST constants N₀ and K, with critical depth.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 1.5 m carbon column, 10 m/h, 50 → 5 mg/LShallow resin bed, 2 m

Results

N₀ and K come from column tests at two or three bed depths (Hutchins' plot of t against Z). The model ignores axial dispersion and changes in velocity.

Service time to breakthrough31.361h
Critical bed depth (t = 0)0.82396m
Bed volumes treated235.21

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 m carbon column, 10 m/h, 50 → 5 mg/L. The inputs, in the units selected above:

InputValue
Bed depth1.5000 m
Superficial velocity10.000 m/h
Feed concentration50.000 mg/L
Breakthrough concentration5.0000 mg/L
Bed capacity N₀20.000 g/L
Rate constant (m³/(kg·h))5.0000 -

Applying the formula below gives:

ResultValue
Service time to breakthrough51.211 h
Critical bed depth (t = 0)0.21972 m
Bed volumes treated341.41

Open this example in the calculator and change any input.

Formula

\(t_b = \frac{N_0Z}{C_0v} - \frac{1}{KC_0}\ln\left(\frac{C_0}{C_b} - 1\right), \quad Z_0 = \frac{v}{KN_0}\ln\left(\frac{C_0}{C_b} - 1\right)\)

Variables

Symbol Meaning SI unit
\(Z\) Bed depth m
\(v\) Superficial velocity m/s
\(C_0\) Feed concentration kg/m³
\(C_b\) Breakthrough concentration kg/m³
\(N_0\) Bed capacity N₀ kg/m³
\(K\) Rate constant (m³/(kg·h)) -
\(t_b\) Service time to breakthrough s
\(Z_0\) Critical bed depth (t = 0) m
\(BV\) Bed volumes treated -

Method and standards

BDST equation.

Where it is used

  • Carbon and resin column design.
  • Scaling from laboratory columns.

Common mistakes

  • Using constants from another velocity range.
  • Extrapolating far beyond tested depths.

Assumptions and limits

  • Constant flow and feed; plug flow.
  • K is entered as a number in m³/(kg·h); it does not change with the unit system.
  • The critical depth is shown only when the breakthrough concentration is below half the feed.

References

  • Bohart–Adams model in Hutchins' BDST form (Hutchins, Chem. Eng. 80(19): 133, 1973); Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 16

Questions and answers

What are N₀ and K?

N₀ is the bed's adsorption capacity per volume; K is the rate constant of transfer from fluid to solid.

What is the critical bed depth?

The depth below which effluent breaks through at once: about the mass-transfer zone length.

What do the defaults represent?

A liquid-phase carbon column removing an organic from 50 to 5 mg/L, with constants from column tests.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.