Worked example
Example: 1.5 m carbon column, 10 m/h, 50 → 5 mg/L. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bed depth | 1.5000 m |
| Superficial velocity | 10.000 m/h |
| Feed concentration | 50.000 mg/L |
| Breakthrough concentration | 5.0000 mg/L |
| Bed capacity N₀ | 20.000 g/L |
| Rate constant (m³/(kg·h)) | 5.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Service time to breakthrough | 51.211 h |
| Critical bed depth (t = 0) | 0.21972 m |
| Bed volumes treated | 341.41 |
Open this example in the calculator and change any input.
Formula
\(t_b = \frac{N_0Z}{C_0v} - \frac{1}{KC_0}\ln\left(\frac{C_0}{C_b} - 1\right), \quad Z_0 = \frac{v}{KN_0}\ln\left(\frac{C_0}{C_b} - 1\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Z\) | Bed depth | m |
| \(v\) | Superficial velocity | m/s |
| \(C_0\) | Feed concentration | kg/m³ |
| \(C_b\) | Breakthrough concentration | kg/m³ |
| \(N_0\) | Bed capacity N₀ | kg/m³ |
| \(K\) | Rate constant (m³/(kg·h)) | - |
| \(t_b\) | Service time to breakthrough | s |
| \(Z_0\) | Critical bed depth (t = 0) | m |
| \(BV\) | Bed volumes treated | - |
Method and standards
BDST equation.
Where it is used
- Carbon and resin column design.
- Scaling from laboratory columns.
Common mistakes
- Using constants from another velocity range.
- Extrapolating far beyond tested depths.
Assumptions and limits
- Constant flow and feed; plug flow.
- K is entered as a number in m³/(kg·h); it does not change with the unit system.
- The critical depth is shown only when the breakthrough concentration is below half the feed.
References
- Bohart–Adams model in Hutchins' BDST form (Hutchins, Chem. Eng. 80(19): 133, 1973); Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 16
Questions and answers
What are N₀ and K?
N₀ is the bed's adsorption capacity per volume; K is the rate constant of transfer from fluid to solid.
What is the critical bed depth?
The depth below which effluent breaks through at once: about the mass-transfer zone length.
What do the defaults represent?
A liquid-phase carbon column removing an organic from 50 to 5 mg/L, with constants from column tests.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.