FireCADCalc

Steam Purity from Carry-over (TDS in Steam)

Dissolved solids carried into the steam by boiler water carry-over, the solids reaching the superheater or turbine per year, and the boiler water TDS a steam purity limit allows.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserBoilerSteam turbine

Inputs

Examples: Boiler water 2000 ppm, 0.1 % carry-over, 20 t/h, steam limit 1 ppm3000 ppm, 0.5 % (foaming), 10 t/h, 3 ppmTurbine boiler: 50 ppm, 0.02 %, 100 t/h, 0.02 ppm

From steam purity tests or the drum internals maker; foaming raises it sharply.

Results

Steam TDS exceeds the limit: lower the boiler water TDS (more blowdown) or improve the drum separators.

Mechanical (droplet) carry-over only: vaporous carry-over of silica, and of salts at high pressure, is not included.

TDS in the steam2.0000ppm
Highest boiler water TDS for the steam limit1,000.0ppm
Solids carried with the steam0.040000kg/h
Solids carried per year320.00kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Boiler water 2000 ppm, 0.1 % carry-over, 20 t/h, steam limit 1 ppm. The inputs, in the units selected above:

InputValue
Boiler water TDS2,000.0 ppm
Mechanical carry-over, share of steam0.10000 %
Steam flow20,000 kg/h
Steam purity limit (TDS in steam)1.0000 ppm
Operating hours per year8,000.0 h

Applying the formula below gives:

ResultValue
TDS in the steam2.0000 ppm
Highest boiler water TDS for the steam limit1,000.0 ppm
Solids carried with the steam0.040000 kg/h
Solids carried per year320.00 kg

Open this example in the calculator and change any input.

Formula

\(C_s = c\,C_{bw} \qquad C_{bw,max} = \frac{C_{lim}}{c} \qquad \dot m_{sol} = \dot m_s\,C_s \qquad m_{yr} = \dot m_{sol}\,t\)

Variables

Symbol Meaning SI unit
\(C_{bw}\) boiler water TDS –
\(c\) mechanical carry-over, share of steam –
\(\dot m_s\) steam flow kg/s
\(C_{lim}\) steam purity limit –
\(t\) operating hours s
\(C_s\) TDS in steam –
\(C_{bw,max}\) highest boiler water TDS –
\(\dot m_{sol}\) solids carried kg/s
\(m_{yr}\) solids per year kg

Method and standards

Solids carried by droplets of boiler water in proportion to the carry-over; mass fractions throughout.

Where it is used

  • Setting boiler water TDS limits for turbine steam.
  • Explaining superheater and turbine deposits.
  • Valuing better drum internals.

Common mistakes

  • Ignoring foaming, which raises carry-over many times.
  • Applying droplet carry-over to silica at high pressure.
  • Using design carry-over without a steam purity test.

Assumptions and limits

  • Mechanical (droplet) carry-over only; steady operation. Vaporous carry-over (silica, and salts at high pressure) is not included; there is no pressure input.
  • A maximum boiler water TDS of 100 % or more means the limit does not restrict it, and none is shown.

References

  • Mass balance of solids carried by droplets

Questions and answers

How pure is my steam?

Carry-over times boiler water TDS. With 2000 ppm in the boiler and 0.1 % carry-over the steam carries 2 ppm, 320 kg of solids a year at 20 t/h; to meet a 1 ppm limit the boiler water must stay below 1000 ppm.

What raises carry-over?

High drum level, foaming (oil, high alkalinity or suspended solids), load swings and damaged separators.

Does this include silica?

Not vaporous silica, which dissolves in high-pressure steam even without droplets; that needs the silica distribution data for the pressure.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.