Worked example
Example: Boiler water 2000 ppm, 0.1 % carry-over, 20 t/h, steam limit 1 ppm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Boiler water TDS | 2,000.0 ppm |
| Mechanical carry-over, share of steam | 0.10000 % |
| Steam flow | 20,000 kg/h |
| Steam purity limit (TDS in steam) | 1.0000 ppm |
| Operating hours per year | 8,000.0 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| TDS in the steam | 2.0000 ppm |
| Highest boiler water TDS for the steam limit | 1,000.0 ppm |
| Solids carried with the steam | 0.040000 kg/h |
| Solids carried per year | 320.00 kg |
Open this example in the calculator and change any input.
Formula
\(C_s = c\,C_{bw} \qquad C_{bw,max} = \frac{C_{lim}}{c} \qquad \dot m_{sol} = \dot m_s\,C_s \qquad m_{yr} = \dot m_{sol}\,t\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_{bw}\) | boiler water TDS | – |
| \(c\) | mechanical carry-over, share of steam | – |
| \(\dot m_s\) | steam flow | kg/s |
| \(C_{lim}\) | steam purity limit | – |
| \(t\) | operating hours | s |
| \(C_s\) | TDS in steam | – |
| \(C_{bw,max}\) | highest boiler water TDS | – |
| \(\dot m_{sol}\) | solids carried | kg/s |
| \(m_{yr}\) | solids per year | kg |
Method and standards
Solids carried by droplets of boiler water in proportion to the carry-over; mass fractions throughout.
Where it is used
- Setting boiler water TDS limits for turbine steam.
- Explaining superheater and turbine deposits.
- Valuing better drum internals.
Common mistakes
- Ignoring foaming, which raises carry-over many times.
- Applying droplet carry-over to silica at high pressure.
- Using design carry-over without a steam purity test.
Assumptions and limits
- Mechanical (droplet) carry-over only; steady operation. Vaporous carry-over (silica, and salts at high pressure) is not included; there is no pressure input.
- A maximum boiler water TDS of 100 % or more means the limit does not restrict it, and none is shown.
References
- Mass balance of solids carried by droplets
Questions and answers
How pure is my steam?
Carry-over times boiler water TDS. With 2000 ppm in the boiler and 0.1 % carry-over the steam carries 2 ppm, 320 kg of solids a year at 20 t/h; to meet a 1 ppm limit the boiler water must stay below 1000 ppm.
What raises carry-over?
High drum level, foaming (oil, high alkalinity or suspended solids), load swings and damaged separators.
Does this include silica?
Not vaporous silica, which dissolves in high-pressure steam even without droplets; that needs the silica distribution data for the pressure.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.