Boiler Phosphate Dosing Rate

Phosphate (TSP) dosing rate for boiler water from feedwater flow and hardness, blowdown and the phosphate residual to keep in the boiler water.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserBoilerWater treatment plant

Inputs

Examples: 10 t/h feed, 2 ppm hardness, 5 % blowdown, 30 ppm PO4 residual, TSP 25 % PO450 t/h, 0.5 ppm, 2 %, 10 ppm, 25 %5 t/h, 5 ppm, 8 %, 40 ppm, anhydrous TSP 57.9 %

From your water chemistry limits for the boiler pressure.
Trisodium phosphate dodecahydrate is about 25 % PO₄; anhydrous about 58 %.

Results

Phosphate feed, as PO₄0.025815kg/h
Product feed0.10326kg/h
Dose in the feedwater, as PO₄0.51629ppm
PO₄ per unit of hardness as CaCO₃0.63259kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h feed, 2 ppm hardness, 5 % blowdown, 30 ppm PO4 residual, TSP 25 % PO4. The inputs, in the units selected above:

InputValue
Feedwater flow10,000 kg/h
Feedwater hardness, as CaCO₃2.0000 ppm
Blowdown, share of feedwater5.0000 %
Phosphate residual to keep in the boiler water, as PO₄30.000 ppm
PO₄ content of the product25.000 %

Applying the formula below gives:

ResultValue
Phosphate feed, as PO₄0.027652 kg/h
Product feed0.11061 kg/h
Dose in the feedwater, as PO₄2.7652 ppm
PO₄ per unit of hardness as CaCO₃0.63259 kg/kg

Open this example in the calculator and change any input.

Formula

\(r = \frac{2\,M_{PO_4}}{3\,M_{CaCO_3}} \qquad \dot m_{PO_4} = \dot m_{fw}\left(H\,r + b\,R_{PO_4}\right) \qquad \dot m_p = \frac{\dot m_{PO_4}}{w} \qquad D = \frac{\dot m_{PO_4}}{\dot m_{fw}}\)

Variables

Symbol Meaning SI unit
\(\dot m_{fw}\) feedwater flow kg/s
\(H\) feedwater hardness as CaCO₃ –
\(b\) blowdown, share of feedwater –
\(R_{PO_4}\) phosphate residual in boiler water –
\(w\) PO₄ content of the product –
\(\dot m_{PO_4}\) phosphate feed as PO₄ kg/s
\(\dot m_p\) product feed kg/s
\(D\) dose in the feedwater –
\(r\) PO₄ per unit hardness as CaCO₃ kg/kg
\(M\) molar masses from IUPAC atomic weights kg/kmol

Method and standards

Phosphate to precipitate hardness as calcium phosphate (3 Ca : 2 PO₄), plus the phosphate leaving with the blowdown at the residual concentration.

Where it is used

  • Internal treatment of low and medium pressure boilers.
  • Setting phosphate pump strokes.
  • Chemical budgets.

Common mistakes

  • Counting hardness as Ca instead of as CaCO₃.
  • Using the product rate as PO₄.
  • Overfeeding phosphate in high-pressure boilers, where it hides out and returns.

Assumptions and limits

  • All hardness reacts as calcium phosphate; residual measured as PO₄.
  • The 3 Ca : 2 PO₄ ratio of tricalcium phosphate is a simple stoichiometric basis, not taken from a cited treatment standard. In alkaline boiler water calcium often precipitates as hydroxyapatite Ca₁₀(PO₄)₆(OH)₂, which takes less phosphate (r ≈ 0.569), and magnesium hardness does not form calcium phosphate; the result is then on the high side.

References

  • Calcium phosphate stoichiometry (3 Ca : 2 PO4)
  • IUPAC 2013 atomic weights

Questions and answers

How much phosphate does a boiler need?

Enough to react with the hardness and to keep the residual in the blowdown. 10 t/h of feedwater with 2 ppm hardness, 5 % blowdown and 30 ppm residual needs 27.7 g/h of PO₄, about 111 g/h of trisodium phosphate dodecahydrate.

Where does 0.633 come from?

Calcium phosphate has 3 calcium for 2 phosphate, so each kg of hardness as CaCO₃ takes 2 × 94.97 / (3 × 100.09) = 0.633 kg of PO₄.

What residual should I keep?

Your water chemistry standard or boiler maker sets it by pressure; this calculator takes it as an input.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.