Worked example
Example: 10 t/h feed, 2 ppm hardness, 5 % blowdown, 30 ppm PO4 residual, TSP 25 % PO4. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feedwater flow | 10,000 kg/h |
| Feedwater hardness, as CaCO₃ | 2.0000 ppm |
| Blowdown, share of feedwater | 5.0000 % |
| Phosphate residual to keep in the boiler water, as PO₄ | 30.000 ppm |
| PO₄ content of the product | 25.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Phosphate feed, as PO₄ | 0.027652 kg/h |
| Product feed | 0.11061 kg/h |
| Dose in the feedwater, as PO₄ | 2.7652 ppm |
| PO₄ per unit of hardness as CaCO₃ | 0.63259 kg/kg |
Open this example in the calculator and change any input.
Formula
\(r = \frac{2\,M_{PO_4}}{3\,M_{CaCO_3}} \qquad \dot m_{PO_4} = \dot m_{fw}\left(H\,r + b\,R_{PO_4}\right) \qquad \dot m_p = \frac{\dot m_{PO_4}}{w} \qquad D = \frac{\dot m_{PO_4}}{\dot m_{fw}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{fw}\) | feedwater flow | kg/s |
| \(H\) | feedwater hardness as CaCO₃ | – |
| \(b\) | blowdown, share of feedwater | – |
| \(R_{PO_4}\) | phosphate residual in boiler water | – |
| \(w\) | PO₄ content of the product | – |
| \(\dot m_{PO_4}\) | phosphate feed as PO₄ | kg/s |
| \(\dot m_p\) | product feed | kg/s |
| \(D\) | dose in the feedwater | – |
| \(r\) | PO₄ per unit hardness as CaCO₃ | kg/kg |
| \(M\) | molar masses from IUPAC atomic weights | kg/kmol |
Method and standards
Phosphate to precipitate hardness as calcium phosphate (3 Ca : 2 PO₄), plus the phosphate leaving with the blowdown at the residual concentration.
Where it is used
- Internal treatment of low and medium pressure boilers.
- Setting phosphate pump strokes.
- Chemical budgets.
Common mistakes
- Counting hardness as Ca instead of as CaCO₃.
- Using the product rate as PO₄.
- Overfeeding phosphate in high-pressure boilers, where it hides out and returns.
Assumptions and limits
- All hardness reacts as calcium phosphate; residual measured as PO₄.
- The 3 Ca : 2 PO₄ ratio of tricalcium phosphate is a simple stoichiometric basis, not taken from a cited treatment standard. In alkaline boiler water calcium often precipitates as hydroxyapatite Ca₁₀(PO₄)₆(OH)₂, which takes less phosphate (r ≈ 0.569), and magnesium hardness does not form calcium phosphate; the result is then on the high side.
References
- Calcium phosphate stoichiometry (3 Ca : 2 PO4)
- IUPAC 2013 atomic weights
Questions and answers
How much phosphate does a boiler need?
Enough to react with the hardness and to keep the residual in the blowdown. 10 t/h of feedwater with 2 ppm hardness, 5 % blowdown and 30 ppm residual needs 27.7 g/h of PO₄, about 111 g/h of trisodium phosphate dodecahydrate.
Where does 0.633 come from?
Calcium phosphate has 3 calcium for 2 phosphate, so each kg of hardness as CaCO₃ takes 2 × 94.97 / (3 × 100.09) = 0.633 kg of PO₄.
What residual should I keep?
Your water chemistry standard or boiler maker sets it by pressure; this calculator takes it as an input.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.