FireCADCalc

Deaerator Oxygen: Steam–Water Equilibrium

Equilibrium oxygen in deaerated water for the steam-phase oxygen at deaerator pressure, and the steam-phase limit for a target (IAPWS G7-04 K_D).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Deaerator and feedwater system

Inputs

Examples: 1.3 bar(a) DA, 2 ppm O2 in steamPressurised DA 4 bar(a)

Results

Equilibrium is the best case: real deaerators approach it only with enough venting, contact time and full heating to saturation.

Saturation temperature143.61°C
Distribution constant y/x14,728
Equilibrium oxygen in the water (by mass)1.2060ppb
Steam-phase oxygen for the target41.460ppm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.3 bar(a) DA, 2 ppm O2 in steam. The inputs, in the units selected above:

InputValue
Deaerator pressure (absolute)1.3000 bar
Oxygen in the steam phase (by volume)2.0000 ppm
Target oxygen in the water (by mass)7.0000 ppb

Applying the formula below gives:

ResultValue
Saturation temperature107.11 °C
Distribution constant y/x52,412
Equilibrium oxygen in the water (by mass)0.067778 ppb
Steam-phase oxygen for the target206.56 ppm

Open this example in the calculator and change any input.

Formula

\(x = \frac{y}{K_D(T_{sat})}, \quad w = x\frac{M_{O_2}}{M_{H_2O}}, \quad y_{max} = K_D\,w_t\frac{M_{H_2O}}{M_{O_2}}\)

Variables

Symbol Meaning SI unit
\(p\) Deaerator pressure (absolute) Pa
\(y\) Oxygen in the steam phase (by volume) -
\(w_t\) Target oxygen in the water (by mass) -
\(T_{sat}\) Saturation temperature K
\(K_D\) Distribution constant y/x -
\(w\) Equilibrium oxygen in the water (by mass) -
\(y_{max}\) Steam-phase oxygen for the target -
\(x\) Oxygen mole fraction in the water -
\(M_{O_2}\) Molar mass of oxygen kg/kmol
\(M_{H_2O}\) Molar mass of water kg/kmol

Method and standards

IAPWS G7-04.

Where it is used

  • Deaerator performance checks.
  • Vent rate studies.

Common mistakes

  • Mass ppb treated as molar ppb.

Assumptions and limits

  • Equilibrium at saturation.
  • If the target would allow a steam phase of more than pure oxygen, y_max is not shown and a note says the target sets no limit.

References

  • IAPWS G7-04
  • Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H₂O and D₂O at High Temperatures (2004); T_sat from IAPWS-IF97

Questions and answers

Why does a deaerator work?

At saturation oxygen strongly prefers the steam phase: K_D is in the tens of thousands near 100 °C.

Why vent?

Venting removes the oxygen-rich steam; without it oxygen builds up in the steam space and returns to the water.

Typical guarantee?

A commonly quoted figure for pressure deaerators is 0.005 cm³/L (about 7 ppb), which is the default target here; use the figure in your own purchase specification.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.