Rod Bundle Subchannel Geometry and Heat Transfer (Weisman)

Flow area, hydraulic diameter, Reynolds number and the Weisman rod-bundle heat transfer coefficient for water flowing along a square or triangular lattice.

Thermal power plant

Inputs

Examples: Illustrative PWR square lattice 12.6 / 9.5 mmTriangular VVER lattice 12.75 / 9.1 mmResearch reactor, low pressure 0.2 MPa, 50 C

Accepted: 1 to 50 mm
Accepted: 1 to 40 mm
Accepted: 0.1 to 30 MPa
Accepted: 6.85 to 366.85 °C
Accepted: 10 to 20,000 kg/(m²·s)

Results

Weisman: Nu = ψ·0.023Re^0.8Pr^0.333 with ψ = 1.826P/D − 1.0430 (square, 1.1 ≤ P/D ≤ 1.3) or 1.130P/D − 0.2609 (triangular, 1.1 ≤ P/D ≤ 1.5). Water and steam properties from IAPWS-IF97.

P/D is outside the range of the correlation.

Pitch-to-diameter ratio1.3333
Flow area per rod142.90mm²
Hydraulic diameter15.162mm
Reynolds number41,614
Prandtl number3.5652
Weisman bundle factor1.3917
Nusselt number242.38
Heat transfer coefficient10,242W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PWR square lattice 12.6 / 9.5 mm. The inputs, in the units selected above:

InputValue
LatticeSquare
Rod pitch12.600 mm
Rod outer diameter9.5000 mm
Coolant pressure15.500 MPa
Bulk coolant temperature310.00 °C
Mass flux3,500.0 kg/(m²·s)

Applying the formula below gives:

ResultValue
Pitch-to-diameter ratio1.3263
Flow area per rod87.878 mm²
Hydraulic diameter11.778 mm
Reynolds number487,548
Prandtl number0.89819
Weisman bundle factor1.3789
Nusselt number1,086.8
Heat transfer coefficient49,889 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(A = P^2 - \frac{\pi D^2}{4}\;\text{or}\;\frac{\sqrt3}{2}P^2 - \frac{\pi D^2}{4}, \quad D_h = \frac{4A}{\pi D}, \quad Nu = \psi\,0.023Re^{0.8}Pr^{0.333}\)

Variables

Symbol Meaning SI unit
\(\text{lattice}\) Lattice -
\(P\) Rod pitch m
\(D\) Rod outer diameter m
\(p\) Coolant pressure Pa
\(T\) Bulk coolant temperature K
\(G\) Mass flux kg/(m²·s)
\(P/D\) Pitch-to-diameter ratio -
\(A_{cell}\) Flow area per rod m²
\(D_h\) Hydraulic diameter m
\(Re\) Reynolds number -
\(Pr\) Prandtl number -
\(\psi\) Weisman bundle factor -
\(Nu\) Nusselt number -
\(h\) Heat transfer coefficient W/(m²·K)

Method and standards

Rod-bundle convection.

Where it is used

  • Fuel assembly thermal design.
  • Heat exchanger rod bundles with longitudinal flow.

Common mistakes

  • Using the tube Dittus–Boelter equation for a tight bundle.
  • Using the whole assembly area instead of the cell per rod.

Assumptions and limits

  • Fully developed turbulent single-phase flow; infinite lattice (no wall subchannels).

References

  • Weisman correlation for longitudinal flow in rod bundles

Questions and answers

Why do bundles transfer heat better than tubes?

The open lattice gives more mixing; Weisman's factor ψ is about 1.2–1.4 at typical pitches, so h exceeds the Dittus–Boelter value for the same hydraulic diameter.

What is the flow area per rod in a triangular lattice?

The hexagonal cell around each rod: (√3/2)P² − πD²/4.

What do the defaults represent?

An illustrative PWR lattice: square, 12.6 mm pitch, 9.5 mm rods, 15.5 MPa, 310 °C and 3,500 kg/(m²·s).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Weisman, Heat transfer to water flowing parallel to tube bundles, Nucl. Sci. Eng. 6 (1959) 78–79, Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.