FireCADCalc

Reflected Reactor Critical Size and Reflector Savings

Bare critical radius of a spherical core and the smaller radius with a reflector, from one-group reflector savings using the reflector constants and thickness.

Thermal power plant

Inputs

Examples: Illustrative k 1.12, M2 300 cm2, 60 cm reflectorGraphite reflector 1 m, L 54 cm, D 0.84Thin water reflector 5 cm, L 2.85 cm

Accepted: 1.0001 to 3
Accepted: 1 to 100,000 cm²
Accepted: 0.01 to 10 cm
Accepted: 0.01 to 10 cm
Accepted: 0.1 to 200 cm
Accepted: 0 to 500 cm

Results

One-group estimate: δ = (D_c/D_r)L_r tanh(T/L_r); a reflector thicker than about two diffusion lengths acts as infinite. Two-group methods are needed when core and reflector spectra differ much.

Material buckling (per cm²)0.004167
Bare critical radius48.669cm
Reflector savings10.066cm
Reflected critical radius38.603cm
Core volume saved50.100%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative k 1.12, M2 300 cm2, 60 cm reflector. The inputs, in the units selected above:

InputValue
Core infinite multiplication factor1.1200 -
Core migration area300.00 cm²
Core diffusion coefficient0.90000 cm
Reflector diffusion coefficient0.92000 cm
Reflector diffusion length54.000 cm
Reflector thickness60.000 cm

Applying the formula below gives:

ResultValue
Material buckling (per cm²)4.0000e-04
Bare critical radius157.08 cm
Reflector savings42.496 cm
Reflected critical radius114.58 cm
Core volume saved61.184 %

Open this example in the calculator and change any input.

Formula

\(R_0 = \frac{\pi}{B}, \quad \delta = \frac{D_c}{D_r}L_r\tanh\frac{T}{L_r}, \quad R = R_0 - \delta\)

Variables

Symbol Meaning SI unit
\(k_\infty\) Core infinite multiplication factor -
\(M^2\) Core migration area m²
\(D_c\) Core diffusion coefficient m
\(D_r\) Reflector diffusion coefficient m
\(L_r\) Reflector diffusion length m
\(T\) Reflector thickness m
\(B^2\) Material buckling (per cm²) -
\(R_0\) Bare critical radius m
\(\delta\) Reflector savings m
\(R\) Reflected critical radius m
\(1 - (R/R_0)^3\) Core volume saved -

Method and standards

Reflector savings.

Where it is used

  • Core and research reactor sizing.
  • Teaching reactor physics.

Common mistakes

  • Using the reflector's own diffusion length for the core.
  • Ignoring that the formula is one-group.

Assumptions and limits

  • Spherical core; one group; homogeneous core and reflector.

References

  • One-group reflector savings

Questions and answers

Why does a reflector shrink the core?

It returns leaking neutrons, so less fuel is needed to make up for leakage; the saving acts like an extra layer of core of thickness δ.

How thick should a reflector be?

About two diffusion lengths: beyond that tanh(T/L_r) is close to 1 and extra thickness adds little.

What do the defaults represent?

An illustrative core (k∞ 1.12, M² 300 cm², D 0.9 cm) with a 60 cm water-like reflector of D 0.92 cm and L 54 cm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.